Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.

Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.

Company Product

  • GCK Low-voltage Draw out Switchgear
  • GCK Low-voltage Draw out Switchgear,Low Voltage Switchgear,Draw out Switchgear,Circuit Breaker Switchgear

    High and Low Voltage Switchgears

    GCK series low voltage draw out switchgear is applicable for three phase four wire/five wire AC power system with rated operation voltage 380V

    Product Description

    GCK series low voltage draw out switchgear is applicable for three phase four wire/five wire AC power system with rated operation voltage 380V, used for electric power receiving and feeding, reactive power compensation, electric energy calculation, lighting and motor centralized control at power plant, substation, mine enterprises, high buildings.

    This product complies with the Standards GB7251 Low-voltage Switchgear and Control Equipment, JB / T9661 Low-voltage Draw out Type Switchgear, IEC 60439-1 Low - voltage Switchgear and Control Equipment.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

     

  • Send Inquiry
  • GGD Low Voltage Fixed-mounted Switchgear
  • GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears

    GGD series low voltage switchgear is used for power lighting

    Product Description

    GGD series low voltage switchgear is used for power lighting, power transformation, distribution and control for AC distribution system with rated frequency 50HZ and rated operation voltage 380V, rated current up to 3150A at power plant, substation, mine enterprises and other users.

    It owns high breaking capability, rated short time withstand current can be up to 50KA, circuit layout is flexible and combination is convenient and so on. It is one of typical products for assembled type, fixed panel switchgear in domestic.

    This product complies with the national standards GB7251 Low-voltage Switchgear and Control Equipment, international standard IEC 60439 Low - voltage Switchgear and Control Equipment.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • Model Indoor AC Metal Clad Intermediate Switchgear
  • KYN28A-12 (GZS1-12) Model Indoor AC Metal Clad Intermediate Switchgear,KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear,Circuit Breaker Switchgear,High and Low Voltage Switchgears,Indoor AC Switchgear

    Product Description

    KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear, this product is suitable for three phase AC power system with rated voltage 12KV and rated frequency 50Hz, is used for receiving and distributing the power energy, to control, protect and monitor the circuit.

     

    Product Features

    Meet the standard: GB3906-97 3-35KV AC Metal-enclosed Switchgear, GB11022-89 High-voltage Switchgear General Technical Conditions, IEC298 (1990) AC Metal-enclosed Switchgear and Control Equipment With Rated Voltage Above 1kv and or Below 50kv , DL404-97 Order Technical Conditions for Indoor AC High Voltage Switchgear Cabinet.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • XGN2 Type Modular High Voltage Switchgear
  • XGN2 Type Modular High Voltage Switchgear,High Voltage Switchgear,High and Low Voltage Switchgears

    XGN2 type modular high-voltage switchgear cabinet is applied to receive and distribute the electrical energy in three-phase AC power system with rated voltage 3, 6, 10KV and rated frequency 50HZ

    Product Description

    XGN2 type modular high-voltage switchgear cabinet is applied to receive and distribute the electrical energy in three-phase AC power system with rated voltage 3, 6, 10KV and rated frequency 50HZ, especially for the frequently operated occasion. Its busbar system is a single busbar (which can derive the single busbar with bypass and double busbar structure). The switchgear cabinet is in line with the requirements of the National Standards GB3906 3-35KV AC Metal-enclosed Switchgear and the international Standard IEC298, also there are proposed "five anti" interlocking functions such as anti-breaking and closing by mistaken for circuit breaker, anti-breaking and closing disconnector switch with load, anti-breaking and closing grounding wire/switch with load, anti closing circuit breaker/disconnector switch with grounding wire/switch, anti entering charged interval by mistaken.

     

    Product Features

    The main switch of the switchgear applies ZN28A-10 series vacuum circuit breakers, equipped with CD117 series of electromagnetic operating mechanism and CT19 series of spring operating mechanism. Using GN-30 rotary isolating switch.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • ZBW Type Prefabricated Substation,mobile transformer substation
  • ZBW Type Prefabricated Substation,mobile transformer substation,distribution transformer substation,power substation transformer

    ZBW Type Prefabricated Substation

    ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 “high and low voltage prefabricated substation” and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation.

    Product Description

    ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 “high and low voltage prefabricated substation” and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation. Such as smaller size, smaller floor area, compact structure, flexible movement, which greatly reduce period and area for construction in site, also the construction cost. Meanwhile, prefabricated substation is easy to be installed at site , can realize rapid power supply, almost maintenance free. Most particularly, it is placed at load center so that reduce power loss effectively to improve power quality, enhance the reliability of power supply and also is significant for distribution network transformation.

    This substation fulfills the functions such as transformation of energy, distribution, transmission, metering, compensation, system control, protection and communication.

     

    The ZBW prefabricated substation is composed by the high-voltage switchgear, low-voltage distribution panel, distribution transformer and enclosure. The high-voltage switchgear adopts air load switch and the transformer is dry-type or oil immersed type. The substation adopts good ventilation structure with elegant appearance and good heat-insulating performance. The temperature rise of the compartments caused by the outdoor solar radiation can be reduced to within the lowest limits on account of the upper and lower ventilation windows. The forced ventilation device and the temperature auto-controlled device should be installed in the substation. The systems of control, protection, live display and the lighting are equipped in each separate unit.

    Product Features

    Application

    The type of small unattended substation is applicable for voltage up to 35KV, with main transformer capacity up to 5000KVA, is widely used in urban industrial substation, 10KV ring network system, rural power grid 35KV substation and other occasions.

    Main Function

    This substation fulfills the functions such as transformation of energy, distribution, transmission, metering, compensation, system control, protection and communication.

    Main Characters

    The primary and secondary equipments are pre-installed in the cabinet which is removable, full-sealed, automatic temperature controlled, antiseptic, damp proof and rustproof. It only needs to be installed on the cement foundation after arriving at the site. This kind of substation have the advantages of low investment, short construction period, small occupation area and easy environmental coordination.

     

    Model and Meaning

    Technical Parameter of ZBW Prefabricated Substation

     

    Description

    Unit

    Data

    HV compartment

    Rated Frequency

    Hz

    50

    Rated voltage

    kV

    6      10      35

    Max operating voltage

    kV

           

    Power frequency withstand voltage(phase to ground and between phases)/ disconnector fracture

    kV

    32/36 42/48 95/118

    lightning impulse withstand voltage(phase to ground and between phases)/ disconnector fracture

    kV

     60/70   75/85   185/215

    Rated current

    A

    400    630

    Ratedshort-time withstand current

    kA

    (2S)   16(2S)    20(2S)

    Rated peak withstand current

    kA

     40  50

    LV compartment

    Rated voltage

    V

    380   200

    Rated current of main circuit

    A

    100~3200

    Rated short-time withstand current

    kA

    15  30  50

    Rated peak withstand current

    kA

    30  63  110

    Branch current

    A

    10 ~ 800

    Number of branch circuits

    /

    1 ~ 12

    Compensation capacity

    kVA R

    0 ~ 360

    Transformer

    Rated capacity

    kVA

    50~2000

    Short-circuit impedance

    %

    4   6

    Tapping range

    /

    ±2× ±5%

    Connection group symbol

    /

    Yyn0   Dyn11

     

     

     

    Technical Parameters

    Notes to the ordering of the Prefabricated Substation

    1. High voltage:

    Way of incoming: terminal type, ring type or double power in.

    Whether there is high voltage metering or not. If yes, the position of the meter(front of the switch or behind the switch), the requirement of the meter gauge and its supplier is designated or not.

    Type of the HV switch, one way is using the combination with high voltage vacuum load switch and the fuse, which is mainly used and economical; the other is adopting the disconnector switch and the vacuum breaker, which is used for the high capacity transformer and with higher price.

    1. Transformer: the transformer type, the connection group symbol, capacity and the impedance voltage of the transformer.
    2. Low voltage:

     Switch Supplier.

     The number of the outgoing ways and the rated current value of each outgoing switch.

     Whether there is the compensation or not, if yes, the capacity of the compensation.

     Whether with the metering or not. If yes, the position is necessary.

    1. Type of the busbar(copper or aluminum)
    2. Layout of the substation(whether with the operation corridor or not)
    3. The material of transformer enclosure: composite board (commonly used), steel plate, stainless board or cement.
    4. Delivery Period for prefabricated substation:

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • SC(B)10 Series Resin-insulated Dry Type Transformer
  • SC(B)10 Series Resin-insulated Dry Type Transformer,cast resin transformer,dry-type transformercast resin dry transformerstep up dry transformer

    Dry Type Transformer

    Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, easy to be installed, low operating costs.

    Product Features

    Function Characteristics:

    • Flame retardant, non-pollution, it can be installed directly in the load center.
    • Maintenance-free, easy to be installed, low operating costs.
    • The enclosure can be of Good moisture resistance, transformer can be put into operation without pre-drying under 100% humidity in the normal operation.
    • Low loss, light weight and small volume, low noise, good dissipation of heat, it can be 150% rated load operation under forced air cooling conditions.
    • Equipped with a complete temperature protection control system to provide reliable protection for the safe operation of transformers.
    • High reliability. The results of checking for the products that has been put into operation show that the reliability index has reached the international advanced level.

     

    Structural Characteristics:

    Foil Coil: Adopting the entire section of copper foil, together with the F-class turn insulation, low voltage winding is wound by the special low-voltage foil winding machine. The foil coil resolves problems such as large short-circuit stress, ampere turn unbalance, poor heat dissipation, existing the winding spiral angle and unsteady manual welding quality due to low voltage and large current coil. At the same time, the end of winding is treated with cast resin, solidification to make shape, moisture-proof and anti-fouling, the lead for copper bar is welded by argon arc welding automatically.

     

    Temperature Control Device: the transformer adopts BWDK series of signal thermometer. The temperature components are embedded in the upper half of the low-voltage coil, can detect and display the temperature of separate phase coil automatically and continuously, also have the functions of over-temperature alarm and trip.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers
  • SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers,Dry type Power Transformers,hermetically sealed transformers,dry type transformer

    Dry Type Transformer

    Product Description

    SG (B) 10 series of non-encapsulated H-class dry-type power transformers adopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.

     

    Model and Meaning

    SC(B)10 Series Resin-insulated Dry Type Transformer

     

    SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers

    Technical Parameter for 6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer

    Rated capacity(KVA)

    Voltage Combination

    Connection Group Symbol

    No-load Loss(W)

    Load Loss (W)

    No-load Current (%)

    Short-circuit Impedance(%)

    High Voltage (KV)

    Tapping ranges of High Voltage

    Low Voltage(KV)

    130℃(B)(100℃)

    155℃(F)(120℃)

    180℃(H)(145℃)

    30

    ±

    Dyn11Yyn0 

    190

    670

    710

    760

    50

    270

    940

    1000

    1070

    80

    370

    1290

    1380

    1480

    100

    400

    1480

    1570

    1690

    125

    470

    1740

    1850

    1980

    160

    540

    2000

    2130

    2280

    200

    ± 

    620

    2370

    2530

    2710

    250

    720

    2590

    2760

    2960

    315

    880

    3270

    3470

    3730

    400

    980

    3750

    3990

    4280

    500

    1150

    4590

    4880

    5230

    630

    1340

    5530

    5880

    6290

    630

    1300

    5610

    5960

    6400

    800

    1520

    6550

    6960

    7460

    1000

    1770

    7650

    8130

    8760

    1250

    2090

    9100

    9690

    10300

    1600

    2450

    11000

    11700

    12500

    2000

    3050

    13600

    14400

    15500

    2500

    3600

    16100

    17100

    18400

    1600

    2450

    1220

    12900

    13900

    2000

    3050

    15000

    15900

    17100

    2500

    3600

    17700

    18800

    20200

    Notes: The load losses listed in the table are the values of the reference temperature for different insulation systems in parentheses; The load losses under other insulation system temperatures that are not included in the table should be according to their respective reference temperatures, the corresponding calculation is based on the"- 155 ℃ (F)" insulation system temperature data.

    Notes: The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.

     

    Technical Parameter for 20kV & 50kVA-2500kVA With Off Circuit Dry Type Transformer

    (KVA)Rated capacity

    Voltage Combination

    Connection Group Symbol

    No-load Loss(W)

    Load Loss (W)

    No-load Current (%)

    Short-circuit Impedance(%)

    High Voltage (KV)

    Tapping ranges of High Voltage

    Low Voltage(KV)

    130℃(B)(100℃)

    155℃(F)(120℃)

    180℃(H)(145℃)

    50

         202224 

    ±

           

         Dyn11Yyn0 

    340

    1160

    1230

    1310

          

    100

    540

    1870

    1990

    2130

    160

    6701.930

    2350

    2470

    3460

    200

        ±

    730

    2770

    2940

    3140

    250

    840

    3220

    3420

    3660

    315

    970

    3850

    4080

    4360

    400

    1150

    4650

    4840

    5180

    500

    1350

    5460

    5790

    6190

    630

    1530

    6450

    6840

    7320

    800

    1750

    7790

    8260

    8840

    1000

    2070

    9220

    9780

    10400

    1250

    2380

    10800

    11500

    12300

    1600

    2790

    13000

    13800

    14800

    2000

    3240

    15400

    16300

    17500

     

    2500

    18200

    19300

    20700

    2000

    3240

    16800

    17800

    19100

    2500

    3870

    20000

    21200

    22700

     

    Technical Parameter for 35kV & 50kVA-2500kVA With Off Circuit Dry Type Transformer

    (KVA)Rated capacity

    Voltage Combination

    Connection Group Symbol

    No-load Loss(W)

    Load Loss (W)

    No-load Current (%)

    Short-circuit Impedance(%)

    High Voltage (KV)

    Tapping ranges of High Voltage

    Low Voltage(KV)

    130℃(B)(100℃)

    155℃(F)(120℃)

    180℃(H)(145℃)

    50

         

    ±

           

         Dyn11Yyn0 

    450

    1340

    1420

    1520

               

    100

    630

    1970

    2090

    2230

    160

    901.930

    2650

    2810

    3000

    200

        ±

    3130

    3320

    3550

    250

    3580

    3800

    4060

    315

    1170

    4250

    4510

    4820

    400

    1370

    5100

    5410

    5790

    500

    1520

    6270

    6650

    7110

    630

    1860

    7250

    7690

    8230

    800

    2160

    8600

    9120

    9760

    1000

    2430

    9860

    10400

    11100

    1250

    2830

    12000

    12700

    13600

    1600

    3240

    14600

    15400

    16500

    2000

    3820

    17200

    18200

    19500

    2500

     

    Technical Parameter for SG(B)10 Series Non-encapsulated Class H Dry-type Transformer

    Product Model No.

    Connection Group Symbol

    Loss  W

    Impedance Voltage(%)

    No-load Current(%)

    Overall Dimension (without enclosure)  mm

    Weight(Kg)

    No-load Loss R

    145℃Load Loss R(W)

    L

    W

    H

    L1

    L2

    d

    f

    SG10-30/10

            Y,yn0D,yn11

    190

    760

           4

    900

    1180

    880

    265

    220

    550

    550

    420

    SG10-50/10

    270

    1070

    940

    1180

    985

    295

    220

    550

    550

    450

    SG10-80/10

    370

    1480

    985

    1180

    1055

    295

    226

    550

    660

    740

    SG10-100/10

    400

    1690

    1010

    1180

    1135

    295

    226

    660

    660

    770

    SG10-125/10

    470

    1980

    1060

    1180

    1175

    306

    228

    660

    820

    1005

    SG10-160/10

    540

    2280

    1120

    1180

    1230

    312

    228

    660

    820

    1015

    SG10-200/10

    620

    2710

    1180

    1230

    1275

    312

    238

    660

    820

    1035

    SG10-250/10

    720

    2960

    1290

    1230

    1330

    315

    238

    660

    820

    1155

    SG10-315/10

    880

    3730

    1320

    1340

    1355

    315

    240

    820

    1070

    1365

    SGB10-400/10

    980

    4280

    1350

    1340

    1435

    315

    240

    820

    1070

    1585

    SGB10-500/10

    1160

    5230

    1395

    1340

    1495

    325

    258

    820

    1070

    1795

    SGB10-630/10

    1345

    6290

    1450

    1340

    1550

    325

    268

    820

    1070

    2265

    SGB10-630/10

    1300

    6400

    1545

    1340

    1445

    325

    268

    820

    1070

    1930

    SGB10-800/10

    1520

    7460

    1590

    1340

    1490

    330

    273

    820

    1070

    2450

    SGB10-1000/10

    1770

    8760

    1680

    1340

    1555

    330

    276

    820

    1070

    2640

    SGB10-1250/10

    2090

    10300

    1710

    1470

    1635

    335

    286

    820

    1070

    3170

    SGB10-1600/10

    2450

    12500

     6

    1800

    1470

    1770

    350

    330

    1070

    1070

    3985

    SGB10-2000/10

    3050

    15500

    1850

    1470

    1890

    350

    346

    1070

    1070

    4850

    SGB10-2500/10

    3600

    18400

    1900

    1470

    2030

    365

    356

    1070

    1070

    5620

    Notes: The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer
  • S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer

    The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.

    Product Description

    The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.

    S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.

     

    Product Features

    • Good Economic Performance

    The no-load loss for S11 series products decreased averagely, no-load current decreased on S9 series.

    • Long Service Life

    Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air, so that extend the service life effectively.

    • High Operation Reliability

    Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.

    • Small Installation Area

    S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.

    Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer

    Rated Capacity (kVA)

    Voltage Combination

    Connection Group Symbol

    No-load Loss R(W)

    Load Loss R(W)75℃

    Impedance Voltage (%)

    No-load Current(%)

    Length L(mm)

    Width W (mm)

    Height H(mm)

    Gauge Horizontal*Vertical(mm)

    Active parts Weight(Kg)

    Oil Weight(Kg)

    Total Weight(Kg)

    (KV) High Voltage

    Tapping Range of High Voltage

    (KV)Low Voltage

    30

    ±5%±2×

    Dyn11Yzn11Yyn0

    100

    630/600

    980

    735

    1145

    400*400

    178

    78

    355

    50

    130

    910/870

    1017

    758

    1205

    450*400

    240

    92

    415

    63

    150

    1090/1040

    1035

    785

    1285

    450*400

    285

    105

    505

    80

    180

    1310/1250

    1065

    800

    1290

    450*400

    330

    110

    540

    100

    200

    1580/1500

    1072

    820

    1305

    450*400

    345

    116

    590

    125

    240

    1890/1800

    1155

    1105

    1310

    450*550

    415

    135

    705

    160

    280

    2310/2200

    1235

    850

    1535

    550*550

    485

    155

    835

    200

    340

    2730/2600

    1282

    860

    1557

    550*550

    582

    168

    965

    250

    400

    3200/3050

    1310

    940

    1605

    550*550

    695

    210

    1135

    315

    480

    3830/3650

    1465

    1120

    1915

    660*650

    855

    255

    1520

    400

    570

    4520/4300

    1440

    1165

    1725

    660*660

    950

    295

    1590

    500

    680

    5410/5150

    1510

    1250

    1845

    660*650

    1150

    320

    1905

    630

    810

    6200

    1650

    1140

    1920

    660*650

    1500

    435

    2015

    800

    980

    7500

    2125

    1175

    2315

    820*820

    1910

    760

    3510

    1000

    1150

    10300

    2150

    1380

    2570

    820*820

    2125

    880

    3850

    1250

    1360

    12000

    2355

    1485

    2570

    820*820

    2605

    960

    4610

    1600

    1640

    14500

    2385

    1750

    2630

    820*820

    3125

    1150

    5420

    2000

    1940

    18300

    1940

    1400

    1700

    820*820

    2420

    780

    4200

    2500

    2290

    21200

    2050

    1480

    1800

    820*820

    2560

    880

    4680

    Notes:

    1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
    2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.

     

    Technical Parameter for S11 Series 20kV Power Transformer With Off Circuit Tap Changer

    Rated capacity(KVA)

    Voltage Combination

    Connection Group Symbol

    No-load Loss(W)

    Load Loss (W)75℃

    No-load Current (%)

    Short-circuit Impedance(%)

    High Voltage (KV)

    Tapping ranges of High Voltage

    Low Voltage(KV)

    30

    20

    ±5% ±2×

    Dyn11Yzn11Yyn0

    100

    690/660

    50

    130

    1010/960

    63

    150

    1200/1150

    80

    180

    1440/1370

    100

    200

    1730/1650

    125

    240

    2080/1980

    160

    290

    2540/2420

    200

    340

    3000/2860

    250

    400

    3520/3350

    315

    480

    4210/4010

    400

    570

    4970/4730

    500

    680

    5940/5660

    630

    810

    6820

    800

    980

    8250

    1000

    1150

    11330

    1250

    1380

    13200

    1600

    1660

    15950

    2000

    1950

    19140

    2500

    2340

    22220

    Notes:

    1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
    2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
    3. The performance parameters in the table are also applicable for HV with dual voltage 20 (10)kV three-phase transformer.

     

    Technical Parameter for S11 Series 35kV Power Transformer With Off Circuit Tap Changer

    Model

    Voltage Combination

    Connection Group Symbol

    No-load Loss (W)75℃

    Load Loss R(W)

    Impedance Voltage (%)

    No-load Current(%)

    Length L(mm)

    Width W(mm)

    Height H(mm)

    Gauge Horizontal*Vertical (mm)

    Active parts Weight(Kg)

    Oil Weight(Kg)

    Total Weight(Kg)

    High Voltage (kV)

    Tapping Range of High Voltage %

    Low Voltage (kV)

    50

    ±2×±5%

    Dyn11/ Yyn0

    160

    1200/1140

    1195

    935

    1825

    660*660

    300

    330

    860

    100

    230

    2010/1910

    1200

    995

    1935

    660*660

    470

    383

    1130

    125

    270

    2370/2260

    1235

    940

    1955

    660*660

    550

    465

    1335

    160

    280

    2820/2680

    1285

    895

    1950

    660*660

    580

    485

    1475

    200

    340

    3320/3160

    1310

    1150

    1985

    660*660

    680

    595

    1755

    250

    400

    3950/3760

    5

    1450

    1090

    2010

    660*660

    860

    650

    2000

    315

    480

    4750/4530

    5

    1930

    1065

    2320

    820*820

    980

    765

    2290

    400

    580

    5740/5470

    5

    1850

    1165

    2015

    820*820

    1170

    885

    2725

    500

    680

    6910/6580

    5

    2045

    1205

    2415

    820*820

    1340

    960

    3090

    630

    830

    7860

    5

    2085

    1240

    2515

    660*660

    1550

    895

    3810

    800

    980

    9400

    5

    2305

    1615

    2685

    820*820

    1990

    1030

    4510

    1000

    1150

    11500

    5

    2545

    1540

    2590

    1070*1070

    2415

    1475

    5055

    1250

    1400

    13900

    0

    2495

    2010

    2675

    820*820

    2480

    1405

    5290

    1600

    1690

    16600

    0

    2680

    2100

    2770

    820*820

    2600

    1490

    5450

    2000

    1990

    19700

    5

    2790

    2180

    2860

    820*820

    2720

    1590

    5600

    2500

    2360

    23200

    5

    2900

    2290

    2980

    1070*1070

    2830

    1720

    5760

    Notes:

    1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
    2. For the transformer of rated capacity up to 500KVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.

     

    S11 Series 35kV 630kVA-31500kVA Three-phase Dual Winding Power Transformer With Off Circuit Tap Changer

    Model

    Voltage Combination

    Connection Group Symbol

    No-load Loss (W)

    Load Loss R(W)

    No-load Current(%)

    Short circuit impedance (%)

    Length L(mm)

    Width W(mm)

    Height H(mm)

    Gauge Horizontal*Vertical (mm)

    Active parts Weight(Kg)

    Oil Weight(Kg)

    Total Weight(Kg)

    High Voltage (kV)

    Tapping Range of High Voltage %

    Low Voltage (kV)

    630

    35

    ±2×±5%

    3.156.31

    Yd11

    830

    7860

    5

    2400

    1700

    2210

    820*820

    2210

    900

    3250

    800

    980

    9400

    5

    2500

    1850

    2390

    820*820

    2350

    1030

    3500

    1000

    1150

    1150

    5

    2700

    1950

    2510

    820*820

    2490

    1180

    3860

    1250

    1400

    1390

    5

    2900

    2050

    2630

    820*820

    2600

    1350

    4350

    1600

    1690

    1660

    5

    3050

    2130

    2750

    820*820

    2810

    1580

    4855

    2000

    2170

    1830

    5

    3105

    2195

    2805

    1070*1070

    2800

    1800

    5300

    2500

    2560

    1960

    5

    3150

    2535

    2980

    1070*1070

    3525

    2060

    7665

    3150

    ±2×±5%

    3.156.31

    3040

    2300

    5

    3920

    2725

    2840

    1070*1070

    3995

    2205

    8565

    4000

    3610

    2730

    5

    3310

    2915

    3070

    1070*1070

    4825

    2560

    10115

    5000

    4320

    3130

    5

    3480

    3020

    3145

    1070*1070

    5700

    2635

    11305

    6300

    5240

    3500

    5

    3590

    2905

    3210

    1475*1475

    7120

    3240

    13510

    8000

    ±2×

    3.153.36.36.61

    YNd11

    7200

    3840

    4070

    3050

    3595

    1475*1475

    8875

    3840

    16690

    10000

    8700

    4530

    4106

    2795

    3655

    2000*1475

    10305

    3600

    17690

    12500

    1000

    5380

    4570

    3010

    3840

    1475*1475

    12830

    4310

    20990

    16000

    1210

    6580

    5235

    3295

    4615

    2000*1475

    16010

    6650

    27660

    20000

    1440

    7950

    5360

    3415

    4660

    2000*1475

    18820

    7600

    32170

    25000

    1700

    9400

    5830

    3810

    4860

    2000*1475

    22360

    9800

    42600

    31500

    2020

    112000

    6290

    4290

    5260

    2000*1475

    25110

    12010

    49960

    Note: the transformer of low voltage 1kV, the connection group symbol is applicable to Dyn11.

    Note: the transformer of rated capacity 3150kVA or above, the -5% tapping position is for maximum current tap.

    Note: the annual average load rate for the transformer is between 35% to 45%, the loss value in the table can obtain the highest operational efficiency.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • S13 series of Three-phase oil Immersed Transformers,three phase transformer
  • S13 series of Three-phase oil Immersed Transformers,three phase transformer,three phase variable transformer,3 phase transformer,three phase power transformer,3 phase step down transformer

    Oil Immersed Transformer

    Model and Meaning

    Model No.

    Rated CapacityKVA

    Rated Voltage KV

    Connection Group Symbol

    Loss W

    No-load Current (%)

    Impedance Voltage(%)

    High Voltage KV

    Tapping Range of High Voltage

    Low VoltageKV

    No-load

    On Load

    S13-M*R-30/10

    30

    10

    ±5%±

    Dyn11Yyn0

    80

    630/600

    S13-M*R-50/10

    50

    100

    910/870

    S13-M*R-80/10

    80

    130

    1310/1250

    S13-M*R-100/10

    100

    150

    1580/1500

    S13-M*R-160/10

    160

    200

    2310/2200

    S13-M*R-200/10

    200

    240

    2730/2600

    S13-M*R-250/10

    250

    290

    3200/3050

    S13-M*R-315/10

    315

    340

    3830/3650

    S13-M*R-400/10

    400

    410

    4520/4300

    S13-M*R-500/10

    500

    480

    5410/5100

    S13-M*R-630/10

    630

    570

    6200

    S13-M*R-800/10

    800

    700

    7500

    S13-M*R-1000/10

    1000

    830

    10300

    S13-M*R-1250/10

    1250

    970

    12000

    S13-M*R-1600/10

    1600

    1170

    14500

    Notes: The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • S(B)H15-M Series Sealed Amorphous Alloy Power Transformer
  • S(B)H15-M Series Sealed Amorphous Alloy Power Transformer,oil immersed transformer,oil immersed power transformer,oil distribution power transformer

    Oil Immersed Transformer

    The transformer is completely hermetical oil-immersed type. The principle is the same as the hermetical power transformer. The basic elements of the amorphous alloy is Iron, nickel, cobalt, boron and carbon etc.

    Product Description

    The transformer is completely hermetical oil-immersed type. The principle is the same as the hermetical power transformer. The basic elements of the amorphous alloy is Iron, nickel, cobalt, boron and carbon etc. It is a kind of isotropic soft magnetic material with low magnetizing power. With thickness and the filling coefficient is reduced to , the amorphous alloy material is very sensitive for stress. The electrical resistivity of the material is 3-6 times of silicon steel sheet and the hardness is 5 times of it.

    Load loss of S(B)H15-M 30~1600/6~10 series transformer can be reduced by 15% on the basis of GB/T6451 standard. The no-load loss can be reduced by 70% on the base of GB/T6451 standard. Amorphous alloy transformer meets the standard JB/T10318-2002 Technical parameter of oil immersed type amorphous alloy transformer.

    Technical Parameter of S(B)H15-M Series Hermetical Amorphous Alloy Power Transformer

    Rated capacity(kVA)

    Voltage and tapping range

    Connection Group Symbol

    No-load Loss(W)

    Load Loss (W)75℃

    No-load current (%)

    Short-circuit impedance(%)

    High Voltage (KV)

    Tapping ranges of High Voltage

    Low Voltage (KV)

    30

    ±5% ±2×

    Dyn11( or ) Yyn0

    130

    630/600

    50

    170

    910/870

    63

    200

    1090/1040

    80

    250

    1310/1250

    100

    290

    1580/1500

    125

    340

    1890/1800

    160

    400

    2310/2200

    200

    480

    2730/2600

    250

    560

    3200/3050

    315

    670

    3830/3560

    400

    800

    4520/4300

    500

    960

    5410/5150

    630

    1200

    6200

    800

    1400

    7500

    1000

    1700

    10300

    1250

    1950

    12000

    1600

    2400

    14500

    2000

     

     

     

     

    750

    17400

    5

     

     

     

     

     

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.

  • Send Inquiry
  • ZS Series Rectifier Transformer
  • ZS Series Rectifier Transformer,oil immersed power transformer,high quality oil transformer,oil immersed power thransformer

    Oil Immersed Transformer

    Rectifier transformers are widely used in electrolytic electrochemistry, transmission, traction, electrostatic precipitators, DC transmission and other systems which need direct current power supply. Our rectifier transformer absorbed the excellent experiences of same industry at home and abroad. Raw materials such as high magnetic silicon steel sheet and high quality oxygen free copper wire are used. We adopt production technology such as advanced integral assembly per phase for windings, the core are laminated by five step-lap method to reduce iron loss and noise, crimped winding connections, precision machining for tank surface and so on, which make technologic performance at the leading level in domestic. We can design and manufacture various types of products according to user’s requirement.

    Model and Meaning

    Technical Parameter of Rectifier Transformer

    Model No.

    (kVA)Rated capacity

    Rated Voltage 

    Connection Group Symbol

    Weight|(kg)

    (KV)grid side

    (V)Valve side

    Weight for Active parts

    Oil Weight

    Total Weight

    ZSS-400/10

    400

    10

    430

    Dyn11

    1015

    380

    1780

    ZSS-500/6

    500

    400

    Dyn11

    1420

    580

    2800

    ZSS-630/6

    630

    400

    Dyn11

    1550

    620

    3040

    ZSS-650/3

    650

    3

    3150

    Dyn11

    1255

    540

    2460

    ZSS-800/6

    800

    6

    400

    Dyn11

    1576

    705

    3045

    ZSS-1000/6

    1000

    6

    440

    Dyn11

    1837

    838

    3580

    ZSS-1000/10

    1000

    10

    420

    Dyn11

    2112

    897

    3860

    ZSS-1250/10

    1250

    10

    440

    Dyn11

    2205

    1090

    4410

    ZSS-1500/10

    1500

    10

    3300

    Dyn11

    2860

    1205

    5260

    ZSS-1600/6

    1600

    400

    Yyn11

    2680

    1145

    5160

    ZSS-1600/10

    1600

    10

    420

    Dyn11

    3110

    1150

    5500

    ZSS-1600/10

    1600

    10

    660

    Dd0

    2750

    1240

    5310

    ZSS-1750/10

    1750

    10

    6300

    Dyn11

    2790

    1190

    5320

    ZSS-1800/10

    1800

    10

    650

    Dd0

    3060

    1345

    5795

    ZSS-1900/10

    1900

    10

    3300

    Yd11

    3353

    1719

    7180

    ZSS-2000/10

    2000

    10

    660

    Dd0

    3185

    1990

    7750

    ZSS-2300/10

    2300

    10

    420

    Dyn11

    3570

    1495

    7020

    ZSS-2400/10

    2400

    10

    750

    Dyn11

    3635

    1535

    7185

    ZSS-2500/10

    2500

    10

    630

    Dyn11

    4180

    1582

    7390

    ZSS-2500/6

    2500

    630

    Dd0

    4260

    1945

    7980

    ZSS-2600/10

    2600

    10

    3300

    Yd1

    3917

    2015

    8845

    ZSS-2700/6

    2700

    630

    Dyn11

    4500

    1990

    8325

    ZSS-2850/10

    2850

    10

    660

    Dd0

    4240

    1810

    7910

    ZSS-3000/6

    3000

    6

    660

    Dd0

    4203

    1744

    7843

    ZSS-3150/10

    3150

    10

    630

    Dd0

    4911

    1993

    8870

    ZSS-3400/6

    3400

    6

    660

    Dd0

    4733

    1933

    8706

    ZSS-3700/10

    3700

    10

    630

    Dyn11

    5505

    2295

    10090

    ZSS-4000/10

    4000

    10

    3300

    Dd0

    5817

    2604

    11640

    ZSS-4650/10

    4650

    10

    1150

    Dy5

    6185

    2800

    12000

    ZSS-5000/10

    5000

    10

    6600

    Dyn11

    6800

    2750

    12600

    ZSSFP7300/10

    7300

    10

    6600

    Dyn11

    9325

    3640

    16620

    ZSSFP8100/10

    8100

    10

    6600

    Dyn11

    11400

    3835

    17940

    ZSSFP9000/10

    9000

    10

    3300

    Yd1

    10280

    5810

    22500

    ZSS-10000/10

    10000

    10

    3300

    Yd1

    11400

    6880

    25680

    ZSSFP-12500/35

    12500

    35

    1130

    Dd0

    16035

    6480

    27150

    ZSSFP-14000/35

    14000

    35

    900

    Dyn11

    18030

    8235

    34290

    ZSSFP-16300/35

    16300

    35

    1100

    Dyn11

    20010

    8950

    37680

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • What Are the Common Drying Methods for Transformers?
  • What Are the Common Drying Methods for Transformers?

    The following are common drying methods for transformers such as H Class Dry Type Transformer for your reference:

    (1) If the transformer drying chamber such as the Dry Type Cast Resin Transformer is not evacuated, the vent hole should be opened on the tank cover or the moisture should be released by the throttle hole.

    (2) When heating with oil, the insulation layer should be installed outside the transformer tank such as the Three Phase Dry Type Transformer. The insulation layer can be insulated with asbestos cloth, glass cloth, etc., and flammable materials should not be used, and corresponding fire prevention measures should be taken.

    (3) In order to improve the drying quality of the winding, there are two major factors that must be carefully considered: one is to control the drying temperature; the other is to increase the vacuum of the transformer equipment. For the first point, general drying equipment can meet the process requirements. For the second point, it is affected by many factors, and must be considered and arranged reasonably to achieve good drying effect.

    (4) During the vacuuming process during drying, it is not suitable to vacuum or dry under low vacuum in the low temperature stage of drying, otherwise it is not conducive to the rise of core temperature and the elimination of moisture, when the temperature rises to 70~ The vacuum is increased at 80 °C. When drying for 1 to 2 hours, the water vapor in the oil tank is more, the heat radiation capability is improved, the internal temperature tends to be uniform, the moisture is gradually reduced, and the heat radiation capability is lowered.

    (5) The method of identifying the insulation after drying and the technical specifications of the transformer for the test. After the transformer has been dried, its insulation performance needs to be fully evaluated to check its drying effect. The identified items, except the casing, are the same as the test items during the overhaul.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

    More Products Please View Hifactory.

  • Send Inquiry
  • What Are the Classifications of Substations?
  • What Are the Classifications of Substations?

    Substations such as the Prefabricated Substation have the following classifications:

    (1) A type of substation. It refers to the exchange of UHV stations, nuclear power, large energy bases (3 million kw and above) and cross-regional (North China, Central China, East China, Northeast, Northwest) 750/500/330kV substation.

    (2) Type II substation. Refers to other than one type of substation, 750/500/330kV substation, power plant substation (1 million kW and above, less than 3 million kW) and inter-provincial liaison 220kV substation, main transformer or busbar outage, switch refusal A substation that causes quaternary and above power grid events.

    (3) Three types of substations. Refers to the 220kV substation other than the second category, the substation of the power plant to the substation (300,000 kW and above, less than 1 million kW), the main transformer or busbar outage, the switch refuses to cause five-level power grid events, for the first level and above Substation that is directly powered by important users.

    (4) Four types of substations. Refers to substations of 35kV and above in addition to the first, second and third categories.

    Note: All 220kV substations in the work area are three types of substations, and all substations below 110kV are four types of substations.
    We supply all kinds of Substation such as the Mobile Transformer Substation. If you have demand, welcome to contact us.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • Dry Type Transformer Structure Type
  • Dry Type Transformer Structure Type

    The Dry type Power Transformer is mainly composed of a core composed of silicon steel sheets and a coil made of epoxy resin. An insulating cylinder is placed between the high and low voltage coils to increase electrical insulation, and the coils are supported and restrained by the spacers, and the components are fastened by overlapping. Parts have anti-loosening properties.

    The Dry Type Transformer' Construction performance:

    (1) Solid insulation encapsulation winding

    (2) does not encapsulate the winding

    Winding: Among the two windings, the higher voltage is the high voltage winding and the lower is the low voltage winding.

    From the relative positions of the high and low voltage windings, the high voltage can be divided into concentric and overlapping types.

    Concentric windings are simple and easy to manufacture, all using this structure.

    The overlapping type is mainly used for special transformers.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • How to Dry the Transformer?
  • How to Dry the Transformer?

    Transformers such as Oil Immersed Transformer are sometimes wet, especially in the summer when the transformer is relatively powerful, and the power intensity is often overloaded. This makes the transformer such as Three Phase Transformer constantly appear new problems, and the humidity will cause the transformer to short-circuit. Phenomenon and problem, because the transformer is too wet, then the transformer needs to be dried. What is the common method and method of drying the transformer? The following are the common drying methods of the transformer for your reference:

    (1) If the drying chamber is not evacuated, the vent hole should be opened on the cover or the moisture can be released by the throttle hole.

    (2) When heating with oil, an insulation layer should be installed outside the fuel tank. Insulation materials such as asbestos cloth and glass cloth can be used for the insulation layer. Flammable materials should not be used, and corresponding fire prevention measures should be taken.

    (3) In order to improve the drying quality of the winding, there are two major factors that must be carefully considered: one is to control the drying temperature; the other is to increase the vacuum of the equipment. For the first point, general drying equipment can meet the process requirements. For the second point, it is affected by many factors, and must be considered and arranged reasonably to achieve good drying effect.

    (4) During the vacuuming process during drying, it is not suitable to vacuum or dry under low vacuum in the low temperature stage of drying, otherwise it is not conducive to the rise of core temperature and the elimination of moisture, when the temperature rises to 70~ The vacuum is increased at 80 °C. When drying for 1 to 2 hours, the water vapor in the oil tank is more, the heat radiation capability is improved, the internal temperature tends to be uniform, the moisture is gradually reduced, and the heat radiation capability is lowered.

    (5) The method of identifying the insulation after drying and the technical specifications of the transformer for the test. After the transformer has been dried, its insulation performance needs to be fully evaluated to check its drying effect. The identified items, except the casing, are the same as the test items during the overhaul.

    The drying of the transformer is handled by the above several methods. Only when the above technical indicators are reached will the transformer be operated more importantly to achieve more performance and efficiency of the transformer.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

     

     

  • Send Inquiry
  • Do You Know What Is The Short Circuit Impedance of The Transformer?
  • Do You Know What Is The Short Circuit Impedance of The Transformer?

    process of using, it is necessary to enhance the continuous improvement of the use and efficiency of the transformer such as Dry Type Transformer. Since the voltage of the transformer such as Cast Resin Transformer is affected by many factors, the voltage is controlled and used. The pressure of adjustment is not the same. The impedance of the short circuit of the transformer is also a major cause of the transformer's operation and one of the most effective means of controlling the voltage. So what is the meaning of the short-circuit impedance of the transformer in actual operation and operation? Here we will give you a detailed introduction:

    Concept A

    Generally, the short-circuit impedance of a transformer refers to the equivalent series impedance Zk=Rk+jXk between the terminals of a pair of windings at a rated frequency and a reference temperature. Since its value is determined by the load test in addition to the calculation, it is customarily referred to as the short-circuit voltage or the impedance voltage.

    Concept B

    The short-circuit impedance is an important item in the performance index of the transformer, and the deviation between the measured value and the specified value at the time of shipment is very strict.

    Influence of transformer short-circuit impedance on transformer operation

    Transformer short-circuit impedance, also called impedance voltage, is defined in the transformer industry: when the secondary winding of the transformer is short-circuited (steady-state), the voltage applied by the primary winding to the rated current is called the impedance voltage Uz. Usually Uz is expressed as a percentage of the rated voltage, ie uz=(Uz/U1n)*100%

    When the transformer is fully loaded, the level of the short-circuit impedance has a certain influence on the output voltage of the secondary side. The short-circuit impedance is small, the voltage drop is small, the short-circuit impedance is large, and the voltage drop is large. When the transformer load is short-circuited, the short-circuit impedance is small, the short-circuit current is large, and the electric power that the transformer is subjected to is large. The short-circuit impedance is large, the short-circuit current is small, and the electric force that the transformer is subjected to is small.

    The above is the impedance effect of the short circuit of the transformer and the basic analysis of the concept for your reference. Everyone can continuously promote the stability and stability of the transformer. In this case, many effects of the transformer will be exerted, and it is safer. 

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

     

  • Send Inquiry
  • Transformer Energy Saving is More and More Popularized
  • Transformer Energy Saving is More and More Popularized

    Transformers such as Three Phase Transformer also have great developments and changes in the development experience, and the process of transformer experience is more complicated. Nowadays, the renewal and replacement of transformers is also relatively fast. There have been many changes in the process of transformer development and change. The current trend of energy-saving transformers is strengthened, and the advantages of energy-saving transformers are better, which saves raw materials and On the basis of energy, its efficiency is further improved.

    The energy saving of transformers such as Three Phase Variable Transformer is a trend, although its promotion is difficult now, it is also a problem for enterprises, but it will gradually improve. For more energy-saving problems of transformers, please consult our manufacturers or pay attention to them. Our website!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • Cooling Method of Oil Immersed Power Transformer
  • Cooling Method of Oil Immersed Power Transformer

    In the operation of the Oil Immersed Power Transformer, the heat of the winding and the iron core is first transmitted to the oil and then transmitted to the cooling medium through the oil. The cooling method of the Oil Immersed Transformer can be divided into the following types according to the capacity:

    1. Natural oil circulation natural cooling (oil immersed self-cooling)
    2. Natural oil circulation air cooling (oil immersion air cooling type)
    3. Forced oil circulation water cooling
    4. Forced oil circulation air cooling

    Normal use condition

    1. Altitude up to 1000m indoors or outdoors
    2. Maximum ambient temperature +40°C maximum daily average temperature +30°C
    3. The highest annual average temperature +20 ° C, the lowest temperature -25 ° C
    4. Transformers that operate under special conditions of use are available upon request.

    We are Oil Immersed Power Transformer Suppleir. If you have demand, welcome to contact us!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • Distinguish Between Dry Type Transformer and Oil Immersed Transformer from The Outside
  • Distinguish Between Dry Type Transformer and Oil Immersed Transformer from The Outside

    The biggest difference between an Oil Immersed Transformer and a Dry Type Transformer is that there is no "oil". Since the oil is liquid and has fluidity, the oil-immersed transformer must have a casing. The inside of the casing is transformer oil, and the oil is immersed in the transformer. The coil does not see the coil of the transformer from the outside; while the dry transformer has no oil, it does not need the outer casing, and can directly see the coil of the transformer; there is also a characteristic that the oil-immersed transformer has an oil pillow on it and is stored inside. Transformer oil, but now the new oil-immersed transformer also has transformers without oil pillows;

    The Power Oill Transformer is convenient for heat dissipation, that is, it is convenient for the internal insulating oil to flow and dissipate heat. The heat sink is designed externally, just like the heat sink, but the dry type transformer does not have this heat sink, and the heat dissipation depends on the fan below the transformer coil. The fan is a bit like an indoor unit for home air conditioning;

    Oil-immersed transformers are usually installed in a separate transformer room or outdoors due to the need for fire protection. The dry-type transformers are definitely installed indoors. Generally, they are installed in the low-voltage power distribution room and installed side by side with the low-voltage power distribution cabinet.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • What is the Line Voltage and Phase Voltage of the Transformer?
  • What is the Line Voltage and Phase Voltage of the Transformer?

    The transformer such as Oil Immersed Transformer is a kind of voltage that can stabilize the voltage in the circuit and ensure the stability of the voltage and current in the circuit. For the transformer, it is a kind of electric equipment, which plays a huge role in various circuits and various kinds of circuits. A variety of advantages. Transformers have their own voltage and current. There are two kinds of transformers on the voltage, one is the line voltage and the phase voltage. They are two different voltages in a transformer. They are related and different. So what is the relationship between them?

    The line voltage is the phase voltage of 3 times the root number, which is the voltage between the hot lines.

    The phase voltage is the voltage between each phase and the neutral line. It is the voltage between each live line and the neutral line.

    The line voltage refers to the voltage from the lead line of the Three Phase Transformer. The phase current refers to the current flowing through a phase coil of the three-phase equipment, and the phase voltage is the voltage applied to a separate set of coils. The phase voltage is the voltage between the phase line and the neutral line. For the delta connection, the line voltage is equal to the phase voltage, and the line current is equal to 3 times the root of the phase current; for the star connection, the line current is equal to the phase current, and the line voltage is equal to 3 times the root of the phase voltage. For practical three-phase equipment, such as transformers, motors, etc., measuring line current line voltage is easier to implement than measuring phase current phase voltage, so the nameplate is marked with line current and line voltage.

    Transformer secondary side load current: line current = phase current, line voltage between three phases, phase and voltage of any phase of the three phases.

    In the symmetrical three-phase circuit, the phase voltage or the line voltage can be used for calculation, but the formula is different.

    Use the line voltage calculation formula:

    P=

    Use the phase voltage calculation formula:

    P=3×U×I

    The introduction of the two voltages of the transformer and the related calculation methods will be introduced here. For the two voltages of the transformer, the functions and various advantages should be exerted to a greater extent to ensure the stability of the transformer voltage and achieve transformer safety. And stable operation!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry