XL-21 low-voltage power distribution cabinet
Overview
XL-21 Low Voltage Switch Cabinet is suitable for power plant, industry and mining enterprises. It is used for power distribution in three-phase four-wire or three-phase five-wire system with AC voltage of 500V or less. XL-21 low-voltage power distribution box is installed on the wall of the indoor device and repaired in front of the screen.
Structural characteristics
XL-21 Low Voltage Switch Cabinet product is closed, the shell is formed by bending steel plate, and the knife switch operating handle is located at the upper part of the right column in front of the box, which can be used for switching power supply. A voltmeter is installed in front of the distribution box to indicate the voltage of bus bar. There is a door in front of the distribution box. When the door is opened, all the equipment in the distribution box is exposed, which is convenient for maintenance. The distribution boxes adopt domestic self-designed components, which have the characteristics of compact structure, convenient maintenance and flexible combination of line schemes. low-voltage power distribution cabinet is equipped with air circuit breaker and fuse as short circuit protection. Contactors and thermal relays are also equipped. The front door of the box can be equipped with operation buttons and indicator lights.
GGD fixed switch cabinet
Standard specification
Overview:
power controlled GGD fixed switch cabinet is suitable for 50HZ AC, 380V rated working voltage and 3150A rated working current distribution system of power plant, power plant, mining enterprise and other power users. It is used for power conversion, distribution and control of power, lighting and distribution equipment.
GGD fixed switchgear is a new type of low-voltage distribution cabinet designed on the principle of safety, economy, reasonableness and reliability, according to the requirements of the superiors in charge of the Ministry of Energy, the vast number of power users and design departments. The product has the characteristics of high breaking ability, good dynamic and thermal stability, flexible electrical scheme, convenient combination, series, strong practicability, novel structure and high protection grade. It can be used as a replacement product of low-voltage switchgear.
Fixed switchgear meets IEC 439 "Low Voltage Switchgear and Control Equipment", GB7251 "Low Voltage Switchgear Set" and other standards.
Conditions of use
Structural characteristics
Complete Set of Products
The following documents and annexes shall be provided for supply:
Instructions for Order
JP outdoor integrated distribution box
Summary
WSD-JP outdoor integrated distribution device is a kind of outdoor integrated distribution device, which integrates measurement, outgoing line, reactive power compensation and other functions. It has the functions of short circuit, overload, overvoltage and leakage protection. It is small in size, beautiful in appearance, economical and practical. It is installed on poles of transformers on outdoor poles. It is a new generation of ideal distribution products for urban and rural power grid transformation.
Structural characteristics
Use of environmental conditions of waterproof outdoor integrated distribution box
GGD Capacitance Compensation Cabinet
Most load types in power system belong to inductive load. In addition, power electronic devices are widely used in power enterprises, so the power factor of power grid is low. Lower power factor reduces equipment utilization ratio, increases power supply investment, damages voltage quality, reduces equipment service life, and greatly increases line loss. In order to improve the energy waste caused by the low power factor of power grid and these unfavorable factors of power supply production, it is necessary to effectively improve the power factor of power grid. Obviously, it is unreasonable and usually impossible for these reactive power to be supplied by generators and transmitted over long distances. Reasonable way is to generate reactive power where reactive power is needed, that is, to increase reactive power compensation equipment and devices.
Generally speaking, low price Capacitance Compensation Cabinet is composed of cabinet shell, bus, circuit breaker, disconnector, thermal relay, contactor, lightning arrester, capacitor, reactor, primary and secondary conductor, terminal row, power factor automatic compensation control device, panel instrument, etc.
III. Basic Principles
In the actual power system, most of the loads are asynchronous motors. The equivalent circuit can be regarded as a series circuit of resistance and inductance. The phase difference between voltage and current is large and the power factor is low. After shunt capacitors are connected, the current of capacitors will offset part of the inductance current, so that the inductance current decreases, the total current decreases, the phase difference between voltage and current decreases, and the power factor increases.
A reactive power automatic controller is installed in the compensation cabinet, which automatically puts in or removes capacitors according to the load force rate. The main function of the controller is to make the load close to the required reactive current, thereby improving the power factor. For enterprises, the main reason is to avoid the penalty of power factor not up to the standard ().
Ⅳ. Main Technical Indicators of Capacitance Compensation Cabinet
Rated operating voltage: AC380V + 15%
Rated operating frequency: 50Hz
Overload capacity: 120%, 1 minute
Switching frequency: kHz (average)
Corresponding time: <10ms
Power loss of the device: When rated at full load, the loss does not exceed 2% of the compensation capacity.
Fifty harmonics and less can be filtered.
Manual and automatic tracking control
Noise: <60dB (1 meter away from device 1)
Protection Level: IP30
Structural Requirements: The cabinet body is installed on the ground with a length * width * height (mm) of 1000 * 1000 * 2260.
One-time Intake: Down Intake
Man-machine interface: Chinese display operation interface.
The following documents and annexes shall be provided for supply:
Hot sale various high quality GGD Capacitance Compensation Cabinet, 50Hz Capacitance Compensation Cabinet from China leading manufacturer. Our products are efficient, cost effective and deliver more benefits. Welcome to choose us!
Microcomputer Controlled Communication Power Supply Screen WSD-GZTW-2
WSD-GZTW-2 is a communication power supply designed for different capacity users. The system configuration consists of monitoring module, communication power module, AC/DC monitoring module, insulation monitoring module, battery patrol module, switch monitoring module, distribution unit, storage battery and cabinet body
Ⅰ.Direct Current Panel
WSD-GZTW-2 Microcomputer Controlled Communication Power Supply Screen is a communication power supply designed for different capacity users. The system configuration consists of monitoring module, communication power module, AC/DC monitoring module, insulation monitoring module, battery patrol module, switch monitoring module, distribution unit, storage battery and cabinet body. It has the characteristics of simple operation, intelligent management, high
Ⅱ.System characteristics
1) Automatic switching of two AC inputs to ensure the normal operation of the system;
2) Wide range of input voltage and strong adaptability of power grid;
3) HZ-JK02T monitor, LCD display, Chinese menu, friendly and rich interface, simple and convenient key operation;
4) It has comprehensive system setup, operation information query and various alarm functions.
5) Intelligent battery charge and discharge management, perfect and reliable temperature compensation function;
6) The rectifier module adopts electrified hot plug-and-pull, which makes daily maintenance convenient and fast.
7) High precision dynamic current sharing, which can operate independently, principally or under control.
8) Extensible battery detection 2 groups 110 knots, insulation detection 240 routes, switch detection 160 routes, compatible with inverter power module, DC conversion module;
9) The system adopts multi-level password authority management to restrict the operation of unauthorized personnel and ensure the safe and reliable operation of the system.
10) Built-in RS232, RS485 two communication interfaces, through the background monitoring and operation monitoring system to implement the "telemetry, remote control, remote communication, remote adjustment" four remote functions, to achieve unattended;
11) Support RTU, CDT, MODBUS three communication protocols.
(1) Signal devices can be added according to user's needs to realize the alarm function of accident signal and warning signal.
(2) The different functions of the configuration will be different. See the function description of the module selected by the Department for details.
Ⅲ.Technical parameter
project |
Parameter index |
Rated input voltage |
380VAC±20% 220VAC±20% |
Rated output voltage |
48VDC、24VDC |
Rated output current |
20A、30A、40A、50A、60A、70A、80A、90A、100A、120A、130A、 |
150A、 180A、200A、260A、300A ...... |
|
Battery capacity |
38Ah、65Ah、100Ah、 150Ah、200Ah、300Ah 500Ah、600Ah、800Ah、 |
1000Ah、1500Ah、2000Ah ...... |
|
stabilized voltage precision |
≤± |
stabilized current precision |
≤± |
Ripple coefficient |
≤± |
Power grid frequency |
50Hz±10% |
Power factor |
≥(Full load output) |
Insulation strength |
>10MΩ、2kVAC No flashover, no breakdown in a minute |
Operation mode |
Continuous long-term operation |
Cooling mode |
Intelligent Temperature Controlled Air Cooling and High Efficiency Natural Cooling |
Audible noise |
≤50dB |
Ⅳ.Use environment of Controlled Communication Power Supply Screen
1) Elevation: no more than 2000 m;
2) ambient temperature: - 10 ~40;
3) Relative humidity: <90% (25 C);
4) Seismic intensity: no more than 8 degrees;
5) The equipment is confined to indoor work with good ventilation;
6) There should be no harmful gases that corrode metals and destroy insulation in the room;
7) Installation vertical inclination: no more than 5 degrees;
9) No strong electromagnetic interference and severe vibration.
The following documents and annexes shall be provided for supply:
High quality microcomputer controlled communication power supply screen, intelligent controlled communication power supply machine are our main you need, welcome to contact us to know more!
PLC control cabinet
PLC control cabinet is an electric cabinet with PLC as the core control unit, which can realize the control of fans, pumps, electric valves and other field equipment. According to the actual control scale, the automatic control of single cabinet can be realized, and the DCS control system can also be composed of multi cabinets through industrial Ethernet or industrial fieldbus network. It is widely used in electric power, metallurgy, chemical industry, paper making, environmental protection sewage treatment and other operations. It can realize remote assistant control, data acquisition, real-time data transmission, online data analysis, large data analysis and application, etc.
Ⅱ. Systematic Programmes and Characteristics
Suitable for small-scale control system. The relay hardware circuit is mainly used to control the system, and the simple automation control is mainly realized. Principle: In manual mode, the user can control the field equipment manually according to the button instructions on the operation panel of the control door; in automatic mode, the small PLC can output the contact signal of the intermediate relay through the logical operation of the program according to the received control conditions, and drive the control unit of the equipment (such as the controlled motor) with this signal. AC contactor, electric control valve, solenoid valve, frequency converter, soft starter, etc., to achieve the purpose of control.
Advantages: Easy operation, low technical requirements for operators. The system runs safely and reliably, maintains conveniently and costs low.
The application of touch screen greatly improves the automation of the system. By using the control of touch screen and PLC, not only the system parameters can be read and written at any time, but also the function of multi-control mode selection can be realized according to its formula function. In addition, because the touch screen has its own storage space, it can record the historical alarm and use process of the system for operators and maintenance personnel to view and analyze. Touch screen pair, analog data recording is also more convenient value view. The bar chart and curve provided by the touch screen are very convenient to record and realize real-time or historical measurement data for users to analyze the operation of the system or control the process reality.
Advantages of Frequency Converter Cabinet : Soft components inside the touch screen can directly send out the intermediate registers inside the PLC, greatly reducing the control buttons and indicator lights on the control cabinet operation panel.
The central control room is equipped with industrial computers with high computing speed and large storage capacity. By connecting field bus with PLC, the data of real-time working condition, process variables, process indexes and process parameters collected by field PLC are displayed to users in the form of graphics, reports and curves, which provide a convenient man-machine interface and centralized management function. Various dispatching instructions and processes are issued by mouse or keyboard. Parameter setting. Users need not worry about the expansion of follow-up equipment. If they add control equipment (such as PLC cabinet), they only need to connect the new equipment to the communication network and load the control program in the configuration software of the host computer.
Advantages of PLC Frequency control cabinet : Stronger communication capability. Industrial configuration software basically covers all communication modes. In addition, the realistic simulation ability is also the characteristic of industrial configuration software. Users only need to observe the running state of field equipment in the central control room, and can operate remotely.
III. PARAMETER INFORMATION
|
Standard type |
Customized |
Core Frequency Converter Components |
SIEMENS Frequency converter |
SIEMENS Inverter or customer provided |
Optional power |
||
Low Voltage Components and Display Instruments (Optional) |
Type A: Low Voltage is Schneider Circuit Breaker and Contactor,Display Instrument is Multifunctional Meter (Including Power and Electricity) |
Type B: Low-voltage circuit breaker and contactor, display instrument is pointer meter. |
Number of control motors |
l One control unit can be selected. Up to one motor to control seven motorsl One of them controls one motor as a standard cabinet, and the other controls two or more motors, which need to be customized. |
|
Alarm instruction |
Yes |
Yes |
485 Interface |
Yes |
Yes |
Local/remote control switching |
Yes |
Yes |
The company mainly product are low voltage switch cabinet, frequency converter cabinet. And we undertake various one-stop services such as preliminary exploration, design, survey, construction, manufacturing, operation and maintenance.
WSD-YBW series Prefabricated Substation
Overview
WSD-YBW series Prefabricated Substation is a series of products designed and developed by our company. This series of products is a complete set of distribution equipment which combines medium-voltage switchgear, transformer and low-voltage distribution equipment according to a certain wiring scheme.
This series of prefabricated substations are suitable for 24kV, rated frequency 50HZ three-phase AC system. The capacity of these substations is allocated to residential quarters, commercial buildings, hotels, large-scale construction sites, high-rise buildings, industrial and mining enterprises and temporary construction sites under 2500KA. They are suitable for power supply in ring network and terminal power supply.
Functional characteristics
Project |
Unit |
High Voltage Equipment |
Transformer Room |
Low Voltage Equipment |
Rated voltage |
KV |
24 |
24/ |
|
Rated current |
A |
630 |
3/75-150/3750 |
Less than 4000 |
Rated Frequency |
Hz |
50 |
||
Rated capacity |
KVA |
50-2500 |
||
Power Frequency Voltage Withstand |
KV |
42/50 |
||
Thunderstorm Pressure Resistance |
KV |
75/125 |
|
|
Shell protection grade |
|
IP23 |
Oil type 55; dry type 65 |
IP23 |
Noise level |
dB |
|
|
|
Shape size |
mm |
According to wiring schematic diagram |
Hot sale various high quality indoor ac metal armored pull-out switchgear, outdoor ac high voltage vacuum circuit breaker, load switch from China leading manufacturer. Our product has high voltage equipment etc international quality system certification.
WSD-ZW32-24GD Outdoor AC high voltage vacuum circuit breaker
Overview
WSD-ZW32-24GD Outdoor AC high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is a rated voltage of 24 KV, 50 HZ three-phase AC outdoor distribution utility model has the advantages of stable and reliable interruption performance, no danger of combustion and explosion, maintenance-free, small size, light weight and long service is mainly used for breaking and closing the load current, overload current and short circuit current in power is suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, and more suitable for rural power grids and frequently operated places.
This product meets GB1984-2003 "High Voltage AC Circuit Breakers" and DL/T402-2007 "Technical Conditions for Order of High Voltage AC Circuit Breakers" and DL/T403-2000 "Technical Conditions for Order of 12 kV~ kV High Voltage Vacuum Circuit Breakers" and other technical standards.
CHARACTERISTICS
Operational sequence
When operating the disconnector, the first step is to confirm that the circuit breaker should be in the open state. Use the insulated tie rod hook to fasten the closing pull ring or the opening pull ring of the operating handle of the isolation closure, pull down slightly, drive the spindle to rotate, open or close the isolation switch. When the spindle rotates the dead point position of the compression spring, a certain tension is maintained so that the blade can be reliably closed or opened to a safe isolation position.
Ⅵ.Standard conditions of use:
Hot sale various high quality high voltage circuit breaker, outdoor ac high voltage vacuum circuit breaker from China leading manufacturer. Our products are efficient, cost effective and deliver more benefits. Welcome to choose us!
WSD-ZW32-24D Outdoor AC high voltage vacuum circuit breaker
Overview
WSD-ZW32-24D Outdoor AC high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is a rated voltage of 24 KV, 50 HZ three-phase AC outdoor distribution equipment.The utility model has the advantages of stable and reliable interruption performance, no danger of combustion and explosion, maintenance-free, small size, light weight and long service is mainly used for breaking and closing the load current, overload current and short circuit current in power is suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, and more suitable for rural power grids and frequently operated places.
This product meets GB1984-2003 "High Voltage AC Circuit Breakers" and DL/T402-2007 "Technical Conditions for Order of High Voltage AC Circuit Breakers" and DL/T403-2000 "Technical Conditions for Order of 12 kV~ kV High Voltage Vacuum Circuit Breakers" and other technical standards.
CHARACTERISTICS of HIGH VOLTAGE CIRCUIT BREAKER
Ⅳ.Standard conditions of use:
Manufacturer of intelligent switch cabinet--low-voltage, high voltage power distribution switch cabinet, also have many other electric equipment electric power accessories, intelligent transmission and distribution automation system"
WSD-VZF(R)-27 Handcart Indoor High Voltage Vacuum Load Switch
Overview
Main uses and scope of application
WSD-VZF(R) -27/630-25 removable vacuum load switch + fuse combination electrical appliances (hereinafter referred to as combination electrical appliances) is a new generation of three-phase AC 50Hz, rated voltage 27kV indoor switchgear developed according to unique design concept and market demand. It is widely used in indoor armoured air insulated switchgear. It meets the requirements of GB3804-2004, GB16926-1997 and other standards. Under normal operating conditions, as long as the technical parameters of the vacuum switch are within the range, it can ensure the safe and reliable operation of the corresponding voltage level of the power grid.
Environmental Conditions for Use
The ambient temperature should not be higher than + 40℃, not lower than – 10℃ (storage and transportation allowed at – 30℃)
Elevation does not exceed 1500m.
Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%, the daily average of saturated vapor pressure is not more than x 10-3 Mpa, and the monthly average is not more than x 10-3 Mpa.
Earthquake intensity does not exceed 8 degrees.
No fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
STRUCTURAL CHARACTERISTICS
Primary structure
The VZF (R) -27 series combination electric apparatus combines current limiting fuse and vacuum interrupter organically by means of "fixed pole" to form a series circuit. The vacuum switch body (vacuum interrupter) is responsible for switching on and off various load currents and overload currents, and the current limiting fuse is responsible for the breaking of short circuit currents.
Overall structure of High Voltage Vacuum Load Switch
The pole pole and the actuator are arranged in one form, which simplifies the transmission link, makes the output characteristics of the mechanism more in line with the load characteristics required by the vacuum switch, reduces the energy consumption and improves the mechanical reliability.
The three-phase pole of a combined electrical appliance is formed by an automatic pressure gel process (APG) to form a "F" pole. The pole column structure avoids the influence of dust and temperature on the insulation of the vacuum arc extinguishing outdoor, reduces the pollution of the shell of the arc chamber, and improves the reliability; the three-phase fuse is installed on the top of the "F" pole, and the structural design takes full account of the electric field of the vacuum switch in the middle switch cabinet. Distribution greatly reduces the adverse effects of inductive components on cabinet withstand voltage test, and improves the insulation strength of cabinet products.
Operating mechanism
The operating mechanism adopts the VS1 spring operating mechanism with the largest consumption in the existing market. Through long-term use and improvement, the performance of the mechanism has been very stable and reliable.
Assembly and Maintenance
The assembly and maintenance of the combined electric appliance are relatively time-saving and labor-saving because of its fixed type and stable and reliable operation mechanism.
Indoor high voltage vacuum load switch is widely used in indoor armored air-insulated switchgear. The Load Switch meets the requirements of GB3804-2004, GB16926-1997 and other standards.
WSD-FLW34-24 SF6 load switch
WSD-FLW34-24 SF6 load switch is suitable for outdoor three-phase AC distribution system with rated voltage of 24 kV and rated frequency of 50/60 HZ.
Overview
WSD-FLW34-24 SF6 load switch is suitable for outdoor three-phase AC distribution system with rated voltage of 24 kV and rated frequency of 50/60 HZ. It can be used for on-off and off-load currents and short-circuit currents. The products are suitable for substation, industrial and mining enterprises, protection and control of farm network, automatic distribution network of farm network and frequent operation places.
WSD-FLW34-24 SF6 load switch is used for operation control switch of overhead line distribution system. There are many types. It has many outstanding advantages, such as no oil, simple mechanism, reliable performance and no maintenance, and has been widely used so far. This High Voltage Switch Cabinets with FDR type fault detector or RTU remote control terminal device to form a very simple distribution automation system, which can realize automatic fault location of overhead lines and automatic isolation of fault sections.
CHARACTERISTICS
Conditions of Use
Our company is specialized in produce outdoor integrated distribution box, outdoor vacuum short circuit, outdoor vacuum circuit breaker. Our products are very popular, if you are interested in our products, please contact us as soon as possible!
KYN28-24 Indoor AC Metal Armored Pull-out Switchgear
KYN28A-24 indoor AC metal armoured pull-out switch cabinet is suitable for three-phase AC 50/60Hz power system, for receiving and distributing power, and for controlling, protecting and testing the circuit. APG epoxy casting and reliable solid insulated bus technology are used in the interior of the product for full insulation design. It has good electric field distribution measures. It is a miniaturized switchgear with advanced technology, stable performance, reasonable structure, convenient use, safety and reliability.
Ⅱ.CHARACTERISTICS of China High Voltage Switch Cabinet
Axial fan heater is a kind of intelligent switch cabinet equipment, if you want to buy high quality heater, you can choose us! Our company is a leader in the industry and we will not disappoint you.
Buy low price, high quality lightning arrester, outdoor lightning arrester, ac gapless metal oxide arrester . You can choose our products. Our company is the leading factory. Warmly welcome new and old customers to visit and patronize!
AC gapless metal oxide arrester
AC gapless metal oxide arrester (hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage.
Product Implementation Standard: GB11032 - 2010 "AC electrical equipment arrester".
is suitable for indoor and outdoor use.
temperature (-40 +40) C;O
maximum solar radiation intensity is
altitude does not exceed 2000 m.
rated frequency of AC system is (48-62) Hz.
power frequency voltage applied between the arrester terminals for a long time should not exceed the continuous operating voltage of the arrester.
7Earthquake intensity 8 degrees and below;
maximum wind speed does not exceed 35m/s.
III. Structure and Characteristics
This kind of arrester is assembled by superposition of non-linear zinc oxide resistors and sealed in high voltage insulating ceramic sleeve without any discharge normal operating voltage, the arrester is insulated with high resistance; when it is impacted by overvoltage, the arrester is in low resistance state, releasing impulse current into the ground quickly, so that the voltage on the electrical equipment parallel to it is limited to the prescribed value, so as to ensure the safe operation of the electrical arrester is equipped with a detachment device. When the arrester operates under overload or suffers accidental damage, the internal pressure increases sharply, so that the arrester can be detached from the device to ensure that the ceramic sleeve is not arrester has the characteristics of good steep wave response, high shock current tolerance, low residual voltage, reliable operation, no power frequency continuous current, simple maintenance and so on.
Sex testing tests, the items are:
(1) DC or power frequency reference voltage test:
When the peak value of DC or AC resistive current flowing through the arrester reaches the reference current, read the voltage value, which is not less than the standard value.
(2) DC leakage current test:
The DC voltage value of is applied at both ends of the arrester (the voltage ripple rate is not more than (+). When the voltage is stabilized, the leakage current flowing through the arrester should not be greater than the standard value. The leakage current of the surge arrester in operation should be no more than 2 times of the measured value before commissioning.
(3) Detection of power frequency persistent current value:
Power Frequency Continuous Current Value, Leakage Current Tester or Sufficient for Use of Arresters
Accurate AC meter detection shows that the RMS or peak resistance current flowing through the arrester under operating power frequency voltage does not exceed times of the initial measurement value.
Ⅵ. Attention:
(1) During transportation and storage, arresters should be placed vertically.
(2) Users are not allowed to disassemble lightning arresters at will.
(3) Users are not allowed to test the working frequency discharge voltage of the arrester in order to avoid damage to the arrester.
(4) Under the condition that users abide by the above rules, our factory is responsible for the three-package matters within the three-package period, which is one year.
If users have special needs, they can write to them. We will supply as required.
The company mainly product are low voltage switch cabinet, frequency converter cabinet. And we undertake various one-stop services such as preliminary exploration, design, survey, construction, manufacturing, operation and maintenance.
(H) RW 12-24 Outdoor High Voltage Drop Fuse
(H) RW 12-27 drop fuse and pull-load drop fuse are outdoor high-voltage protective appliances, which are assembled on the high-voltage side of distribution transformer or branch lines of distribution line, and are used for overload and short-circuit protection of transmission lines and power transformers and for sharing rated load current.
The drop fuse consists of two parts: insulating bracket and fuse pipe. The static contacts are installed at both ends of the insulating bracket, and the movable contacts are installed at both ends of the fuse pipe. The fuse pipe consists of an inner arc extinguishing tube and an outer epoxy glass tube. Pull-load drop fuse adds elastic auxiliary head and arc extinguishing cover to divide and close load current. When a drop fuse is in normal operation, the fuse pipe is tensioned by means of the fuse.
Then a closed position is formed. When the system fails, the fault current causes the fuse to fuse rapidly and form an arc. The arc extinguishing tube is heated by the arc and decomposes a large number of gases, which forms a high pressure in the tube and blows longitudinally along the pipeline. The arc is rapidly elongated and extinguished. After the fuse is fused, the lower moving contact loses tension and turns down. The locking mechanism releases the fuse tube, and the fuse tube falls down, forming an obvious breaking position. When the load needs to be pulled, the contact is pulled by the insulating rod. At this time, the active and static contacts are still in contact. The contacts are pulled by the insulating rod, and the auxiliary contacts are separated. Arc is generated between the auxiliary contacts. The arc is elongated in the slot of the arc extinguishing hood. At the same time, the arc is extinguished when the current passes zero.
The product performance conforms to national standard and IEC282-2 international standard.
Manufacturer of intelligent switch cabinet--low-voltage, high voltage power distribution switch cabinet, also have many other electric equipment electric power accessories, intelligent transmission and distribution automation system
Y5WZ-17-45 AC Gapless MOA
AC gapless metal oxide arrester (hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage.
indoor AC gapless metal oxide arrester(hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage.
Product Implementation Standard: GB11032 - 2010 "AC Gapless Metal Oxide Arrester".
III. Structure and Characteristics
This kind of arrester is assembled by superposition of non-linear zinc oxide resistors and sealed in high voltage insulating ceramic sleeve without any discharge normal operating voltage, the arrester is insulated with high resistance; when it is impacted by overvoltage, the arrester is in low resistance state, releasing impulse current into the ground quickly, so that the voltage on the electrical equipment parallel to it is limited to the prescribed value, so as to ensure the safe operation of the electrical arrester is equipped with a detachment device. When the arrester operates under overload or suffers accidental damage, the internal pressure increases sharply, so that the arrester can be detached from the device to ensure that the ceramic sleeve is not arrester has the characteristics of good steep wave response, high shock current tolerance, low residual voltage, reliable operation, no power frequency continuous current, simple maintenance and so on.
Sex testing tests, the items are:
(1) DC or power frequency reference voltage test:
When the peak value of DC or AC resistive current flowing through the arrester reaches the reference current, read the voltage value, which is not less than the standard value.
(2) DC leakage current test:
The DC voltage value of is applied at both ends of the arrester (the voltage ripple rate is not more than (+). When the voltage is stabilized, the leakage current flowing through the arrester should not be greater than the standard value. The leakage current of the surge arrester in operation should be no more than 2 times of the measured value before commissioning.
(3) Detection of power frequency persistent current value:
Power Frequency Continuous Current Value, Leakage Current Tester or Sufficient for Use of Arresters
Accurate AC meter detection shows that the RMS or peak resistance current flowing through the arrester under operating power frequency voltage does not exceed times of the initial measurement value.
Ⅵ. Attention:
(1) During transportation and storage, arresters should be placed vertically.
(2) Users are not allowed to disassemble lightning arresters at will.
(3) Users are not allowed to test the working frequency discharge voltage of the arrester in order to avoid damage to the arrester.
(4) Under the condition that users abide by the above rules, our factory is responsible for the three-package matters within the three-package period, which is one year.
If users have special needs, they can write to them. We will supply as required.
If you have any question on Industrial frequency converter cabinet, plc control cabinet. We will give the professional answers to your short questions. If you need, welcome to contact us to know more!
Intelligent Transmission and Distribution Automation System
This product is the monitoring unit of the overhead line power grid. It cooperates with the On-post switch to realize automatic monitoring, fault analysis and judgment record of line status. It has the functions of driving switch to protect the safety of line equipment, cut off line fault and automatically restore line operation. Suitable for Outdoor Switchgear up to 35kV including vacuum circuit breaker, oil circuit breaker and gas circuit breaker.
This product is an integrated automatic outdoor measurement and control device which integrates line protection, control, voltage and current signal measurement and monitoring. It has all the functions of processing all voltage and current signals of a single overhead line and remote operation of switches.
Supporting communication modes: wireless mode (GSM/GPRS/CDMA), ethernet, WIFI, optical fiber, power carrier, RS232/485,
RJ45 and so on, and can access other station equipment (such as TTU, FTU, DTU, etc.).
Ⅲ. Functional characteristics of distribution automation system
Ⅳ. Installation indication and outline dimensions of products
Our wifi intelligent transmission and distribution automation system have high quality and cheap price. If you have any question on product, we will give the professional answers to your short questions.
China Indoor Metal Armored Removable High Voltage Switchgear - China Switch Cabinet, Distribution
China Low Voltage Draw out Switchgear - China Draw out Type, Power Distribution Cabinet
MNS Low-voltage extraction switchgear is mainly composed of some combined motor control units and other functional units. These units are mounted in a closed metal cabinet by overlapping the upper and lower parts. Each cabinet body is connected with a horizontal bus set above the cabinet body, and the functional units of the same cabinet body are connected with a vertical bus in parallel. The cabinet body is divided into four isolation zones: horizontal bus zone, vertical bus zone, cable zone and equipment installation zone. Functional units are installed in their respective small rooms. When any functional unit has an accident, it will not affect other units and prevent the accident from expanding.
China Outdoor Low Voltage Power Distribution Box - China Power Distribution, Low Voltage
Xl-21 series power distribution box is suitable for power distribution and lighting distribution in industrial and civil buildings with AC frequency of 50 Hz, voltage of 500 V and below, three-phase four wire power system. At the same time, it is suitable for making all kinds of motor starting cabinets, including full voltage direct starting cabinet, full digital control soft starting cabinet, self coupling step-down starting cabinet, star delta starting cabinet, multi speed motor starting cabinet, etc. There are dozens of primary line scheme numbers or derived scheme numbers for selection, which have a wide range of applications.
This product is an indoor enclosed distribution box. The box body is made of thin steel plate by bending and welding. The front of the box body is a single left door. The door is equipped with voltmeter, ammeter and other measuring instruments, operating appliances and signal appliances. It is a power distribution device with simple structure, reliable operation and low cost.