Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.

Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.

Company Product

  • How To Sample Transformer Oil?
  • How To Sample Transformer Oil?

    The method and process of taking Transformer Oil samples are as follows:

    (1) sampling of transformer oil is necessary for the test of transformer oil. Sampling should be done on dry sunny days. The container and sampling method used in sampling have the most direct influence on whether the actual quality of oil can be truly reflected. The oil sample for the pressure test shall not be less than , and the simplified oil sample shall not be less than 1kg.

    (2) the sampling container shall be a colorless glass bottle with a or 1kg wide mouth frosted glass stopper. Two or three bottles should be collected at a time for analysis and testing. Samples should be labeled with attention to sample name, source, sample date, sampler, weather conditions and other information.

    (3) before the sampling container is used, it should be washed with gasoline, soap liquid or other oil removing solvent (such as trisodium phosphate), and then rinsed with water until it is not alkaline and water can flow evenly from the bottle wall. Finally, wash them several times with distilled water. Wash the sample container of 105 ℃ baking in the oven, will the cork lid tightly after cooling, before use may not open them.

    (4) after sampling, wrap the glass stopper firmly with clean paper or cloth to prevent dirt and water from contaminating the bottle mouth.

    (5) outdoor sampling shall be carried out in dry weather with fine weather or low humidity. During sampling, sundries such as rain, snow or sand shall be strictly prevented.

    (6) for the oil in the oil storage equipment, it shall be normally left for more than 8h before sampling; Sampling on a working transformer does not require standing.

    (7) before and after sampling, clean or non-wool muslin should be applied to wipe and wipe around the sampling mouth.

    (8) when the oil sample of the Oil Transformer in operation is taken, the oil discharge valve or sampling valve under the oil tank should first release about 2kg of dirty oil accumulated at the bottom to clean the oil drain hole, and then take the oil sample.

    (9) when taking the new oil supplemented by transformer and the oil sample that has just been filtered, the oil sample can only be taken after sufficient standing.

    (10) when sampling from a small transformer without a drain pipe (or oil sample valve), glass tube can be inserted into the transformer when it is not in operation to extract the oil sample at the bottom, or the sampling can be replaced by changing oil.

    (11) from the fuel tank, sampling, after open the lid, wash and dry the glass pipe insert oil, thumb pressure nozzle at the same time, after being inserted to loosen the thumb, break down the oil into the tube, then the thumb pressure pipe, glass pipe is put forward, a rotation, a drain pipe of oil, with washing sample tube, so repeated twice, and then draw sample.

    (12) for sampling in batch drums, samples shall be selected at 5% of the total number of oil drums, but not less than 2 barrels. Sampling shall be carried out in whole lot of small pails or bottles at the rate of 2% of the total number of pails (bottles).

    (13) when taking oil samples, the safety and fire prevention regulations on site shall be strictly observed.

    Transformer oil is the essential weapon for transformer operation, and it is the powerful guarantee for transformer operation. The quality of transformer oil must be well mastered, and the transformer oil with appropriate and high quality should be purchased, so as to obtain the best operation effect and function.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • What Is Unexcited Voltage Regulation Of Transformer?
  • What Is Unexcited Voltage Regulation Of Transformer?

    What is the unexcited voltage regulation of transformer? Let's take a shared from Oil Immersed Transformer supplier.

    Non-field excitation changer is relative to on-load voltage regulating, have the load tap switch need to be considered when switching to stream of transformer, ensure continuous current, not affect the power grid, but no excitation regulating power refers to the state of voltage regulation, tap-changer stream. Don't need the transformer in the concrete operation, should have the power of the transformer and load switch are cut off. If the high voltage side has isolation switch, should also open. And the transformer bushing are grounded, and then to switch the load tap switch. Of course you are dry, there is no tap switch, you can go to the tap.

    When the side voltage of the transformer power supply fluctuates up and down,such as 3 Phase Transformer, the number of turns on the original side of the transformer needs to be adjusted to keep the voltage stability of the output side of the transformer as far as possible. There are usually two kinds of voltage regulation: on-load voltage regulation (with load for voltage regulation) and no-load voltage regulation (with load for voltage regulation). Because some people said in the past "no load regulation" is not accurate, it is easy to be misunderstood, that can not carry the load, and do not cut the original side of the power supply voltage, voltage regulation. Therefore,, the exact statement should be called no excitation voltage regulation, that is, the transformer in the case of no excitation voltage regulation (to cut off the original side of the transformer power supply, and then the voltage regulation).

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

     

  • Send Inquiry
  • Transformer Fault Reasons And Preventive Measures
  • Transformer Fault Reasons And Preventive Measures

    Oill Transformer Manufacturer tells us that operators should be familiar with the causes of transformer faults so that they can take timely treatment and preventive measures. Transformer is an extremely important electrical equipment in the transmission and distribution system. Compared with other electrical equipment, its failure rate is very low. But once the failure occurs, it will bring serious losses to industrial and agricultural production. In order to make the electrical operation and maintenance personnel can do regular inspection and maintenance work, eliminate equipment defects, to ensure the safe operation of transformers, transformers put into operation, the common fault is: insulation oil deterioration, lightning, lead insulation fault, casing damage, tap switch fault and other fault reasons. Let us understand the transformer in detail after the operation are prone to what fault problems.

    Transformer fault reasons and preventive measures:

    Transformer is an extremely important electrical equipment in the transmission and distribution system. Such as Three Phase Transformer,Compared with other electrical equipment, its failure rate is very low. But once the failure occurs, it will bring serious losses to industrial and agricultural production. In order to make the electrical operation and maintenance personnel can do regular inspection and maintenance work, eliminate equipment defects, to ensure the safe operation of transformers, based on many years of transformer operation, maintenance experience analysis of the main causes of failure and preventive measures.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • How To Prevent The Failure Of Transformer Operation?
  • How To Prevent The Failure Of Transformer Operation?

    Oil Immersed Transformer Manufacturer shares that operators should be familiar with the causes of transformer faults so that they can take timely treatment and preventive measures. Transformer is an extremely important electrical equipment in the transmission and distribution system. Compared with other electrical equipment, its failure rate is very low. But once the failure occurs, it will bring serious losses to industrial and agricultural production. In order to make the electrical operation and maintenance personnel can do regular inspection and maintenance work, eliminate equipment defects, to ensure the safe operation of transformers, transformers put into operation, the common fault is: insulation oil deterioration, lightning, lead insulation fault, casing damage, tap switch fault and other fault reasons. Let us understand the transformer in detail after the operation are prone to what fault problems?

    Transformer fault reasons and preventive measures:

    Transformer is an extremely important electrical equipment in the transmission and distribution system. Compared with other electrical equipment, its failure rate is very low. But once the failure occurs, it will bring serious losses to industrial and agricultural production. In order to make the electrical operation and maintenance personnel can do regular inspection and maintenance work, eliminate equipment defects, to ensure the safe operation of transformers, based on many years of transformer operation, maintenance experience analysis of the main causes of failure and preventive measures.

    1. Insulation oil deterioration

    Insulating oil may come into contact with air during operation and gradually absorb moisture from the air to reduce the insulating performance. Insulating oil also could absorb, dissolved air in great quantities, because the oil often run at higher temperatures, oil contact with the oxygen in the air, produce various oxides, and the oxide are acidic, and easy to use copper, aluminum, iron, insulation materials from corrosion, to increase the dielectric loss of oil, the oil degradation, the transformer internal flashover, puncture accidents.

    Welcome to purchase our Dry Type Transformer!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • How To Prevent The Failure Of Transformer Operation?
  • How To Prevent The Failure Of Transformer Operation?

    1. Fault caused by over voltage

    Oil Immersed Transformer Manufacturer When the running transformer is struck by lightning, it will cause overvoltage outside the transformer due to the high potential of lightning. When some parameters of power system change, the overvoltage inside transformer will be caused by electromagnetic oscillation. The transformer damage caused by these two kinds of overvoltages is mostly the main insulation breakdown of windings, resulting in transformer faults. In order to prevent transformer fault caused by overvoltage, it is generally required to install lightning arrester protection on the high voltage side of the transformer, and also install lightning arrester on the low voltage side.

    1. Lead insulation failure

    As a result of the transformer lead connection welding is not firm, joint screw loose, poor contact, causing local overheating, lead burning. In the installation of electrical appliances, the lead is too close to the oil tank, or the lead is too small in the distance between the two, when there is a strong wind or a short circuit occurs outside, the lead is subjected to the action of external force or electric power, it will swing, resulting in the short circuit between the two. If the transformer leakage phenomenon, so that the transformer is seriously short of oil, resulting in the lead part exposed to the air. The insulation level is lowered, and internal flashover and breakdown occur. In addition, if the transformer outlet occurs many short circuit, will make the winding stress deformation cause inter-turn insulation damage, and short circuit fault.

    Welcome to purchase our oil immersed transformer!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

     

  • Send Inquiry
  • Transformer energy-saving more and more popularize
  • Transformer energy-saving more and more popularize

    Dry Type Transformer Manufacturer shares that the transformer also has the very big development and the change in carries on the development experience, to the transformer experience process is also quite complex. Now the renewal of the transformer and generation is also relatively fast, for developing and changing process of transformer, also appeared a lot of changes in the trend of current transformer energy-saving is more strengthened, more good advantages of energy saving transformer, made on the basis of saving raw materials and energy, more to improve its efficiency.

    China transformer has experienced the replacement process from S7, S8, S9, S10, S11 and other series. In the mid-1980s, the Chinese government forced the adoption of S7 series low-loss distribution transformers to phase out the high-energy transformers of jb1300-73 and jb500-64 standards that were then in operation on the power grid nationwide. Since 1998, urban and rural power grids have been upgraded nationwide, with S9 series distribution transformers replacing S7 series. In recent years, large quantities of S13 and S15 products are adopted again in the transformation of national urban network and rural network, and the no-load loss of S9 type transformer is reduced by 50-80% compared with that of S9 type transformer.

    Of course, the implementation of energy-saving transformer is also a very difficult thing, due to raw materials and other factors, energy-saving transformer price is much higher than traditional transformer. In order to better promote the application of energy-saving transformers, the ministry of finance, the ministry of industry and information technology and the national development and reform commission jointly issued in 2012 the "implementation rules for the promotion and implementation of energy-saving products and energy-saving power distribution transformers for the project of benefiting the people", which provided 4-30 yuan/kva financial subsidies for energy-saving transformers. However, due to the large number of small and medium-sized transformer manufacturers, the transformer manufacturers are scattered, with excess capacity and many potential quality problems, which also limits the development of energy-saving transformer industry.

    Transformer energy saving is a trend, although it is now the promotion is difficult, for the enterprise is also a problem, but slowly will continue to improve, more about the transformer energy saving problems please consult our manufacturers or attention to our website!

    Welcome to purchase our dry type transformer!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • Working principle of transformer
  • Working principle of transformer

    Three phase transformer Manufacturer shares that transformer is a kind of electric appliance that transfers electric energy or transmits signal from one circuit to another circuit by using electromagnetic induction principle. When there is an alternating current in the primary coil, an alternating flux is generated in the core, causing the voltage (or current) to be induced in the secondary coil. A transformer consists of an iron core and a coil. The coil has two or more windings. The windings connected to the power supply are called primary windings and the rest are called secondary windings.

    By changing the winding ratio of the two coils, different voltages will be obtained in the second coil l. based on this principle, the transformer is a device that transforms the ac voltage, current and impedance. The primary coil and the secondary coil are wound in an appropriate ratio, which can increase or decrease the voltage in the circuit. Can be expressed by the formula, namely;

    Primary voltage (U1)/ secondary voltage (U2)= primary winding number (n1)/ secondary winding number (n2)

    It should be noted that any transformer can only transfer electrical energy from the primary to the secondary. The ratio of the primary and secondary voltages of a transformer is equal to the ratio of the secondary and primary currents. It can be said that the primary input power is equal to the secondary output power without considering the loss of the transformer.

    Welcome to purchase our three phase transformer!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here

    More Products Please View Hifactory.

     

  • Send Inquiry
  • How to see the oil position of oil-immersed transformer?
  • How to see the oil position of oil-immersed transformer?

    1. The connecting pipe is based on the principle of the connecting device. A red ball in the glass pipe indicates the oil level, which is very intuitive.
    2. The pointer position of oil level gauge marked some direct Pointers indicate the fuel oil storage cabinet, or by different temperature corresponding curve (usually three, corresponding to different minimum ring temperature region: such as oil-immersed transformeroil level gage to 30 °, + 20 ° and + 40 °, respectively is refers to the oil-immersed transformer at ambient temperature was minus 30 °, + 20 ° and + 40 ° normal oil level line.) , according to the position of the pointer to convert the amount of oil in the oil storage tank.
    3. For the bellows type, the top of the bellows shall indicate the normal oil level of the oil storage tank corresponding to different oil temperatures.

    3 phase transformer exporter shares that according to different situations, at present, the capacity of 630kVA and below 10kV oil-immersed transformer almost has no oil storage tank, so it is unnecessary to observe the oil level. Oil storage tank is installed in 35kV and above voltage grade or 10kV oil-immersed transformer with larger capacity. The oil level indication of oil storage tank is in such several forms as connecting pipe, pointer type oil level gauge and bellows. The connecting pipe adopts the principle of the connecting device. There is a red ball in the glass pipe to indicate the oil level, which is very intuitive. Pointer type oil level gauge some directly mark the position indicated by the pointer indicates the amount of oil in the oil storage tank, or through the different temperature corresponding curve (generally three, corresponding to the lowest temperature of the region), according to the location of the pointer conversion out of the oil in the oil storage tank; The top of the bellows is used to indicate the normal oil level of the oil storage tank with different oil temperatures (generally, the oil content of the oil storage tank is about 10% of the oil weight of the body).

    The above is the common oil-immersed transformer common oil level measurement and the main way and method of understanding for your reference, for oil-immersed transformer you have any other questions please pay attention to our manufacturers or with our technical personnel to communicate and exchange it!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

     

  • Send Inquiry
  • Why are transformers mostly used in parallel?
  • Why are transformers mostly used in parallel?

    Transformer in the process of running has run in parallel and series operation, but are used in most of the use of parallel operation, parallel operation of the transformer makes it better optimization and utilization of resources, and brings out the performance of the transformer is more important to that transformer parallel operation can connect the transformer stations are more, the performance is also easier to play out, the transformer is basic way of connecting the parallel running way. What is the basic meaning of parallel operation of transformers? Why use parallel operation? Please refer to the detailed explanation of the transformer manufacturer:

    Transformer parallel operation its significance lies in: when a failure occurs, a transformer parallel running of other transformer can continue to run, to ensure that the power use, or when the transformer overhaul to make parallel transformer as the standby transformer, the transformer can be ensured plan maintenance, and can guarantee uninterrupted power supply, improve the reliability of power supply. Improve the capacity of the grid: due to the seasonal power load, power load is bigger, in the summer and in winter electricity load is small can run out of part of the transformer, reduce no-load loss caused by the transformer operation process, to improve the efficiency of the power grid, and can reduce the reactive excitation current, the change of the power factor of power grid.

    The parallel operation of transformers is of great significance, which is helpful for the performance and functions of transformers, so that transformers can improve efficiency and make more contributions to the development of economy and productivity. For more information about transformer shunt, please consult our factory or get in touch with our technicians.

    That's all for the sharing,and we also supply  3 phase transformer,if you have any demand,welcome to purchase our products.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

  • Send Inquiry
  • What's the transformer for?
  • What's the transformer for?

    Transformer is the core of power equipment, such as 3 phase power transformer,which is closely related to people's production and life. It is made by using the principle of electromagnetic induction. The role of transformer in the circuit is mainly to stabilize the performance of voltage and current, making the current and voltage in the circuit more effective. The role of the transformer is still relatively large, for the role of the transformer you have to carefully understand. For common transformer related functions you need to grasp the following content:

    1. Voltage transformation

    A transformer is a component that converts voltage. In practical applications, we often need to change the voltage of the alternating current to suit various needs.

    1. Impedance transformation

    The transformer has the function of impedance transformation. Transformer primary and secondary winding number is different from the secondary reflection to the primary impedance is also different. The ratio of transformer secondary impedance Z2 to primary impedance Z1 is equal to the square of the ratio of transformer secondary winding number N2 to primary winding number N1, that is, Z2/Z1=(N2/N1)2. The impedance transformation of the transformer can make the impedance of both ends of the circuit match well, so as to transmit the maximum signal power.

    1. Phase transformation

    The transformer from 3 phase power transformer manufacturer China has the phase transformation function, the exchange transformer coil joint, may change the signal voltage the phase. For example, using the audio input transformer in the push-pull power amplifier, the original signal and the inverting signal can be distributed to two power amplifiers, so that they can alternately amplify the positive and negative half-cycle signals.

    The role of the transformer to be more carefully to master, and constantly improve the understanding, so that the transformer performance is more improved, more improved in the use of the role, so for the use, maintenance and maintenance of the transformer is a good help. More information about transformer please pay attention to our website!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here.

     

    More Products Please View Hifactory.

     

  • Send Inquiry
  • Dry transformer for sale China Assembly of dry type transformers
  • Dry transformer for sale China Assembly of dry type transformers

    Assembly of dry type transformers

    Dry type transformer common operation is more important, generally speaking, dry type transformer in the process of installation is also to pay attention to a lot of problems, dry type transformer installation needs to pay attention to the matters are more. Dry type transformer installation process is also used in a lot of assembly, so that the composition of the dry type transformer will be more smooth, more scientific. What are the common ways to compose a dry type transformer and the common sequence of processes? Or with the dry type transformer manufacturer to have a look:

    Various methods and corresponding steps for the assembly of dry type transformers are specified as follows:

    1. equipment and material preparation

    The dry type transformer shall be fitted with nameplate. Name of manufacturer, rated capacity, primary and secondary rated capacity, primary and secondary rated voltage, current, impedance, voltage % and wiring group and other technical data shall be indicated on the nameplate.

    The capacity, specification and model of dry type transformer must meet the design requirements. Annex spare parts complete, and have factory certificates and technical documents.

    Section steel: all types of section steel should meet the design requirements, and no obvious corrosion.

    Bolts: except for anchor bolts and shockproof device bolts, galvanized bolts shall be used, together with the corresponding plain washer and spring pad.

    Other materials: welding rod, anti-rust paint, blending paint, etc. Should meet the design requirements, and have product qualification certificate.

    Two, the main machine

    Handling and hoisting equipment: car crane, car, winch, chain, three-step, rail, wire rope, belt rope, roller.

    Installation tools, bench drill, grinding wheel, electric welding machine, welding tools, electric hammer, vise, live wrench, ð ¨ +  head, set

    Test instruments: steel tape measure, steel plate ruler, level gauge, wire drop, meter, multimeter, bridge and test instruments.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here

    More Products Please View Hifactory.

  • Send Inquiry
  • The oil-immersed transformer is set at a distance from the periphery
  • The oil-immersed transformer is set at a distance from the periphery

    Oil-immersed transformer is an important type of transformer, its use is more extensive, for oil-immersed transformer, its safety is more important, do not appear any danger is ok. The common oil-immersed transformer and the distance between the building is clearly specified, must be in accordance with the relevant standards for design and installation is possible, otherwise the performance and effect of oil-immersed transformer will not be better to play out. So what are the common distances? What are the rules? Let's have a look together with our oil-immersed transformer factory:

    The safe distance between the oil-immersed transformer and the building is 5 meters. In accordance with the national standard gb50053-94 "10kv and the following substation design specifications" provisions, outdoor oil-immersed transformer from any building more than 5 meters, in accordance with the national standard "building design fire code" gb50016-2006 provisions, outdoor oil-immersed transformer from civil buildings more than 6 meters. The national standard also states that it is not appropriate to "set up" high-voltage transformers in residential areas. The national standard also stated in 2008 that the distance between the outdoor oil-immersed transformer and the residence should be kept at more than 10 meters, which requires that in the residential areas where residents gather, it is not appropriate to "set up" the oil-immersed transformer of the high-voltage facilities, which is to ensure the safety of people's lives and property needs!

    Above is the common oil immersion type transformer safe distance from the building for your reference, the installation of the time to be strictly in accordance with the relevant distance for installation and design, to ensure that its safety performance continues to improve!

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here

    More Products Please View Hifactory.

  • Send Inquiry
  • Transformers for sale]How can oil-immersed transformers reduce copper loss?
  • Transformers for sale]How can oil-immersed transformers reduce copper loss?

    How can the copper loss of transformer be reduced in long - term operation? Shared by oil immersed transformer supplier.

    1. Lower current density is selected; Reduce the number of turns, but will increase the magnetic flux density of the core and increase the iron loss, when the copper loss is significantly higher than the iron loss, use with caution;
    2. The transformer process should be changed to reduce the ac resistance of the windings. The main methods include reducing the copper wire diameter (not reducing the total cross-sectional area), increasing the adjacent surface of the primary stage (increasing the distributed capacitance of the primary stage), reducing the distance of the primary stage (increasing the distributed capacitance of the primary stage), and reducing the coil sparsity. Change circuit operating parameters to reduce ac resistance, such as switching frequency, but will increase the magnetic flux density of the core and increase the iron loss, when the copper loss is significantly higher than the iron loss, use with caution; Use lower resistivity conductors. Reduce iron loss.
    3. Switch to magnetic core material with better power consumption parameters, such as replacing PC40 material with PC50 material of TDK; Reduce the flux density, but will increase the number of coil turns and lead to copper loss increase, careful use; Change circuit parameters, such as reduce the switching frequency, but at the same time increase the flux density, careful use, if necessary with the winding turns adjustment; Reasonable thermal design, using the core material temperature and loss curve of the valley.

    That's all for the sharing,and we supply oil  immersed transformer for sale, if you have any demand for our products,just feel free to contact us.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here

    More Products Please View Hifactory.

     

  • Send Inquiry
  • Why are some pebbles placed around the transformer?
  • Why are some pebbles placed around the transformer?

    Transformer is a kind of important equipment and type, such as the three phase oil immersed transformer,which is constantly used in production and daily life. It attaches great importance to production and is also the key to improve production efficiency. But when we look at the operation of the transformer, we will find that there are a lot of pebbles around the transformer, and you will often see it in the process of transformer construction and various ground projects. Do you know why pebbles are placed around transformers?

    The lower part of the oil-immersed transformer is usually called the oil discharge tank or oil discharge tank, which leads to the emergency oil pit or the emergency oil tank. In case of an accident, such as oil injection or explosion, the oil of the transformer will flow into the discharge pit through the goose-stone and then flow to the oil pool of the accident. At this time, the goose-stone under the transformer plays an isolating role to reduce the fire and help extinguish the fire. In addition, the high temperature transformer oil can reduce the fire after being cooled by goose stone. Prevent the transformer from burning when it is on fire, and the oil drain hole at the bottom of the oil drain pit will not be blocked. Oil in the transformer goose stone gap between the flow to the below, the surface to avoid oil, oil leakage when it also plays a role in cooling oil temperature, to prevent oil combustion.
    Oil-immersed transformer is placed around pebbles with reason, for transformer to prevent the occurrence of fire burn out or you have more important significance and function of the land, for transformer, to enhance the efficiency of its various realization, let the transformer is more safe and efficient operation, more safety and quickly run to achieve transformer!

    That's all for the sharing,and we supply high quality oil transformer for sale, if you have any demand for our products,just feel free to contact us.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here

    More Products Please View Hifactory.

  • Send Inquiry
  • How much damage does the electromagnetic radiation of the power transformer have on the body?
  • How much damage does the electromagnetic radiation of the power transformer have on the body?

    How much does the electromagnetism radiation of power transformer harm to the body?

    Distribution transformer substation supplier shares that with the improvement of living standards, now we use a variety of electrical appliances also relatively have a lot of electromagnetic radiation, we are called electromagnetic radiation pollution. Transformer is also around us, so relative to the transformer so big power equipment, its electromagnetic radiation how much? Can cause harm to human body? Let's learn about the electromagnetic radiation of the transformer.

    High quality oil transformer radiation is not harmful to human body. During the operation of transformer, transformer radiation will be generated. If the electromagnetic radiation exceeds the prescribed energy limit, electromagnetic radiation pollution will be formed. Electromagnetic radiation pollution can cause a lot of harm, among them the harm to human body basically is to cause human body plant nerve function disorder, blood pressure, blood phase is maladjusted, injure an eye even. Our mankind itself is in all sorts of electromagnetism radiate surround in, natural magnetic field, sunshine can give out the radiation with different intensity, nevertheless only when radiate intensity exceeds certain value (safe value) ability produces harm to human body, namely the electromagnetism pollution that we say commonly.

    When we turn on the TV at home, the electromagnetic field around us is much stronger than the transmission line. Earth itself has a magnetic field, the earth magnetic field and magnetic fields produced by transmission facilities, can also be interesting conclusion: the magnetic field data observed in Beijing for 54 tesla, when magnetic field inversion, a maximum intensity is about 100 micro tesla, 50-100 times that of electromagnetic transmission facilities. This means that people living in the electromagnetic fields of dozens of micro-teslas can hardly feel anything, and even the workers on duty 24 hours a day in the substation will have no impact on their health.

    About the electromagnetic radiation of transformer, in fact, is negligible, but for the sake of safety, or suggest that we stay away from it, so as not to harm the human body.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

  • Send Inquiry
  • What is the unexcited voltage regulation of transformer?
  • What is the unexcited voltage regulation of transformer?

    What is the unexcited voltage regulation of transformer? Shared by power transformers supplier.Let's take a look.

    Non-field excitation changer is relative to on-load voltage regulating, have the load tap switch need to be considered when switching to stream of transformer, ensure continuous current, not affect the power grid, but no excitation regulating power refers to the state of voltage regulation, tap-changer stream. Don't need the transformer in the concrete operation, should have the power of the transformer and load switch are cut off. If there is a disconnecting switch on the high voltage side, it should also be turned on. And the bushing of the transformer are grounded, and then go to switch no load tap switch. Of course you are dry change, no tap switch, you can go to change tap.

    When the voltage on the power side of the transformer fluctuates, it is necessary to adjust the number of turns on the primary side of the transformer, so as to keep the output voltage of the secondary side of the transformer as stable as possible. Generally, there are two kinds of voltage regulation: on-load voltage regulation (with load) and no-load voltage regulation (without load). As someone said in the past "no load voltage regulation" is not accurate, easy to be misunderstood, that can not carry the load, without cutting the original side of the supply voltage, voltage regulation. Therefore, the exact words should be called no excitation voltage regulation, that is, the transformer without excitation under the condition of voltage regulation (to cut off the original side of the transformer power supply, voltage regulation)...

    That's all for the sharing,and we supply power transformers for sale, if you have any demand for our products,just feel free to contact us.

    The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

    If you want to know more about the product, please click here

    More Products Please View Hifactory.

     

  • Send Inquiry
  • oil immersed power thransformer
  • Oil Immersed Transformer

    Rectifier transformers are widely used in electrolytic electrochemistry, transmission, traction, electrostatic precipitators, DC transmission and other systems which need direct current power supply. Our rectifier transformer absorbed the excellent experiences of same industry at home and abroad. Raw materials such as high magnetic silicon steel sheet and high quality oxygen free copper wire are used. We adopt production technology such as advanced integral assembly per phase for windings, the core are laminated by five step-lap method to reduce iron loss and noise, crimped winding connections, precision machining for tank surface and so on, which make technologic performance at the leading level in domestic. We can design and manufacture various types of products according to user’s requirement.

    Model and Meaning

    Technical Parameter of Rectifier Transformer

    Model No.

    (kVA)Rated capacity

    Rated Voltage 

    Connection Group Symbol

    Weight|(kg)

    (KV)grid side

    (V)Valve side

    Weight for Active parts

    Oil Weight

    Total Weight

    ZSS-400/10

    400

    10

    430

    Dyn11

    1015

    380

    1780

    ZSS-500/6

    500

    400

    Dyn11

    1420

    580

    2800

    ZSS-630/6

    630

    400

    Dyn11

    1550

    620

    3040

    ZSS-650/3

    650

    3

    3150

    Dyn11

    1255

    540

    2460

    ZSS-800/6

    800

    6

    400

    Dyn11

    1576

    705

    3045

    ZSS-1000/6

    1000

    6

    440

    Dyn11

    1837

    838

    3580

    ZSS-1000/10

    1000

    10

    420

    Dyn11

    2112

    897

    3860

    ZSS-1250/10

    1250

    10

    440

    Dyn11

    2205

    1090

    4410

    ZSS-1500/10

    1500

    10

    3300

    Dyn11

    2860

    1205

    5260

    ZSS-1600/6

    1600

    400

    Yyn11

    2680

    1145

    5160

    ZSS-1600/10

    1600

    10

    420

    Dyn11

    3110

    1150

    5500

    ZSS-1600/10

    1600

    10

    660

    Dd0

    2750

    1240

    5310

    ZSS-1750/10

    1750

    10

    6300

    Dyn11

    2790

    1190

    5320

    ZSS-1800/10

    1800

    10

    650

    Dd0

    3060

    1345

    5795

    ZSS-1900/10

    1900

    10

    3300

    Yd11

    3353

    1719

    7180

    ZSS-2000/10

    2000

    10

    660

    Dd0

    3185

    1990

    7750

    ZSS-2300/10

    2300

    10

    420

    Dyn11

    3570

    1495

    7020

    ZSS-2400/10

    2400

    10

    750

    Dyn11

    3635

    1535

    7185

    ZSS-2500/10

    2500

    10

    630

    Dyn11

    4180

    1582

    7390

    ZSS-2500/6

    2500

    630

    Dd0

    4260

    1945

    7980

    ZSS-2600/10

    2600

    10

    3300

    Yd1

    3917

    2015

    8845

    ZSS-2700/6

    2700

    630

    Dyn11

    4500

    1990

    8325

    ZSS-2850/10

    2850

    10

    660

    Dd0

    4240

    1810

    7910

    ZSS-3000/6

    3000

    6

    660

    Dd0

    4203

    1744

    7843

    ZSS-3150/10

    3150

    10

    630

    Dd0

    4911

    1993

    8870

    ZSS-3400/6

    3400

    6

    660

    Dd0

    4733

    1933

    8706

    ZSS-3700/10

    3700

    10

    630

    Dyn11

    5505

    2295

    10090

    ZSS-4000/10

    4000

    10

    3300

    Dd0

    5817

    2604

    11640

    ZSS-4650/10

    4650

    10

    1150

    Dy5

    6185

    2800

    12000

    ZSS-5000/10

    5000

    10

    6600

    Dyn11

    6800

    2750

    12600

    ZSSFP7300/10

    7300

    10

    6600

    Dyn11

    9325

    3640

    16620

    ZSSFP8100/10

    8100

    10

    6600

    Dyn11

    11400

    3835

    17940

    ZSSFP9000/10

    9000

    10

    3300

    Yd1

    10280

    5810

    22500

    ZSS-10000/10

    10000

    10

    3300

    Yd1

    11400

    6880

    25680

    ZSSFP-12500/35

    12500

    35

    1130

    Dd0

    16035

    6480

    27150

    ZSSFP-14000/35

    14000

    35

    900

    Dyn11

    18030

    8235

    34290

    ZSSFP-16300/35

    16300

    35

    1100

    Dyn11

    20010

    8950

    37680

    We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you want to know more about the product, please click here.

  • Send Inquiry
  • distribution transformer
  • The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.

    Product Description

    The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.

    S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.

     

    Product Features

    • Good Economic Performance

    The no-load loss for S11 series products decreased averagely, no-load current decreased on S9 series.

    • Long Service Life

    Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air, so that extend the service life effectively.

    • High Operation Reliability

    Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.

    • Small Installation Area

    S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.

  • Send Inquiry