PLT Filter FIRC100-SE10
PLT Filter
PLT filter Supplier
Designed for 1 unit of platelet rich plasma from 450~500ml of whole blood. Features
Designed for 1 unit of platelet rich plasma from 450~500ml of whole blood.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
The platelet recovery rate not less than 85%
Consistent flow rate
PLT Filter FIPL01K-HE00
PLT Filter
PLT filter Supplier
Designed for 5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital.
Features
Designed for 5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
The platelet recovery rate not less than 85%
Consistent flow rate
PLT Filter FBPL01K-HE00
PLT Filter
PLT filter Supplier
Features
Designed for 5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
The platelet recovery rate not less than 85%
Consistent flow rate
Specifications
Product Ref. No. |
FIPL01K-HE00 |
Designed for |
5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital |
Type |
For red cell bed side or laboratory use |
Special feature |
Blood should leave the body for at least 4 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x106 |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate or Acrylonitrile Butadiene Styrene plastic |
(PC / ABS) |
|
Priming volume (ml) |
11ml |
PLT Filter FBPL01K-HE01
PLT Filter
PLT filter Supplier
Features
Designed for 5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
The platelet recovery rate not less than 85%
Consistent flow rate
Specifications
Product Ref. No. |
FIPL01K-HE00 |
Designed for |
5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital |
Type |
For red cell bed side or laboratory use |
Special feature |
Blood should leave the body for at least 4 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x106 |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate or Acrylonitrile Butadiene Styrene plastic |
(PC / ABS) |
|
Priming volume (ml) |
11ml |
PLT Filter FSPL01K-HE01
PLT Filter
PLT filter Supplier
Features
Designed for 5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
The platelet recovery rate not less than 85%
Consistent flow rate
Specifications
Product Ref. No. |
FIPL01K-HE00 |
Designed for |
5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital |
Type |
For red cell bed side or laboratory use |
Special feature |
Blood should leave the body for at least 4 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x106 |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate or Acrylonitrile Butadiene Styrene plastic |
(PC / ABS) |
|
Priming volume (ml) |
11ml |
RBCs Filter FIBC450-SE10
RBCs Filter
RBCs filters Manufacturer, red blood cell filter wholesaler
Designed for 1 unit of RBC suspension from 450/500ml of whole blood. Features
Designed for 1 unit of RBC suspension from 450/500ml of whole blood.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
Post-filtration RBC recovery rate not less than 90%
Consistent flow rate
RBCs Filter FIPP450-SE10
RBCs Filter
Leukocyte Reduction Filter
RBCs filters Manufacturer, red blood cell filter wholesaler
Designed for 1 unit of RBC suspension from 450/500ml of whole blood. Features
Designed for 1 unit of RBC suspension from 450/500ml of whole blood.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
Post-filtration RBC recovery rate not less than 88%
Consistent flow rate
Specifications
Product Ref. No. |
FIPP450-SE10 |
Designed for |
1 unit of RBC suspension from 450/500ml of whole blood |
Type |
In-line use |
Separation way |
For PRP way |
Special feature |
Blood should leave the body for at least 4 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x106 |
Housing |
Soft |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polyvinyl chloride (PVC) |
Priming volume (ml) |
35ml |
RBCs Filter FIRC450-HX10
RBCs Filter
Leukocyte Reduction Filter
RBCs filters Manufacturer, red blood cell filter wholesaler
Designed for 1 unit of RBC suspension from 450/500ml of whole blood. Features
Designed for 1 unit of RBC suspension from 450/500ml of whole blood.
Super high efficiency leukocyte reduction filter (Residual leukocytes <1x105)
Post-filtration RBC recovery rate not less than 88%
Consistent flow rate
Specifications
Product Ref. No. |
FIBC450-HX10 |
Designed for |
1 unit of RBC suspension from 450/500ml of whole blood |
Type |
For RBC bed side or laboratory use |
Special feature |
Blood should leave the body at least 8 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x105 |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate or Acrylonitrile Butadiene Styrene plastic(PC / ABS) |
Priming volume (ml) |
30ml |
RBCs Filter FIRC450-HE10
RBCs Filter
Leukocyte Reduction Filter
Leukocyte Reduction Filter Supplier, Leukocyte Reduction Filter manufacturer
Designed for 1 unit of RBC suspension from 450/500ml of whole blood. Features
Designed for 1 unit of RBC suspension from 450/500ml of whole blood.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
Post-filtration RBC recovery rate not less than 88%
Consistent flow rate
Specifications
Product Ref. No. |
FIBC450-HE10 |
Designed for |
1 unit of RBC suspension from 450/500ml of whole blood |
Type |
For RBC bed side or laboratory use |
Special feature |
Blood should leave the body for at least 8 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x106 |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate or Acrylonitrile Butadiene Styrene plastic(PC / ABS) |
Priming volume (ml) |
30ml |
RBCs Filter FSRC450-HE11
RBCs Filter
Leukocyte Reduction Filter
Leukocyte Reduction Filter Supplier, Leukocyte Reduction Filter manufacturer
Features
Designed for 1 unit of RBC suspension from 450/500ml of whole blood.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
Post-filtration RBC recovery rate not less than 88%
Consistent flow rate
WB Filter FIWB450-HX10
WB Filter
white blood cell filter, WB filters for filter warm blood
Designed for 1 unit of whole blood (WB) volume 450ml or 500ml.
Features
Designed for 1 unit of whole blood (WB) volume 450ml or 500ml.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
High leukocyte reduction (Residual leukocytes <1x105)
High post-filtration whole blood volume recovery rate >91%
Consistent flow rate
WB Filter FIWB450-HE10
WB Filter
white blood cell filter, WB filters for filter warm blood
Designed for 1 unit of whole blood (WB) volume 450ml.
Features
Designed for 1 unit of whole blood (WB) volume 450ml.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
High post-filtration whole blood volume recovery rate >91%
Consistent flow rate
Specifications
Product Ref. No. |
FIWB450-HE10 |
Designed for |
1 unit of WB volume 450ml |
Type |
In-line use |
Special feature |
Warm blood filtration |
Filtration Efficiency level(Residual leukocyte /unit) |
< 1x106) |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate (PC) |
Priming volume (ml) |
40ml |
WB Filter FIWB450-SX10
WB Filter
Leukocyte Reduction Filter
leukocyte filter, leukodepletion blood filter
Designed for 1 unit of whole blood (WB) volume 450ml.
Features
Designed for 1 unit of whole blood (WB) volume 450ml.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
Super high efficiency leukocyte reduction filter (Residual leukocytes <1x105)
High post-filtration whole blood volume recovery rate >90%
Consistent flow rate
Specifications
Product Ref. No. |
FIWB450-SX10 |
Designed for |
1 unit of WB volume 450ml |
Type |
In-line use |
Special feature |
Warm blood filtration |
Filtration Efficiency level(Residual leukocytes /unit) |
< 1x105 |
Housing |
Soft |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polyvinyl chloride (PVC) |
Priming volume (ml) |
44ml |
WB Filter FIWB450-SE10
WB Filter
Leukocyte Reduction Filter
leukocyte filter system, Leukocyte Reduction Filter
Designed for 1 unit of whole blood (WB) volume 450ml.
Features
Designed for 1 unit of whole blood (WB) volume 450ml.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
High post-filtration whole blood volume recovery rate >90%
Consistent flow rate
Specifications
Product Ref. No. |
FIWB450-SE10 |
Designed for |
1 unit of WB volume 450ml |
Type |
In-line use |
Special feature |
Warm blood filtration |
Filtration Efficiency level(Residual leukocytes /unit) |
< 1x106 |
Housing |
Soft |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polyvinyl chloride (PVC) |
Priming volume (ml) |
42ml |
WB Filter FSWB450-HE11
WB Filter
Leukocyte Reduction Filter
Leukocyte Reduction Filter Supplier, leukodepletion blood filter
Features
Designed for 1 unit of whole blood (WB) volume 450ml.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
High post-filtration whole blood volume recovery rate >91%
Consistent flow rate
Specifications
Product Ref. No. |
FSWB450-HE11 |
Designed for |
1 unit of WB volume 450ml |
Type |
In-line use |
Special feature |
Warm blood filtration |
Filtration Efficiency level(Residual leukocyte /unit) |
< 1x106) |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate (PC) |
Priming volume (ml) |
40ml |
WB Filter FBWB450-HE10
WB Filter
Leukocyte Reduction Filter
Features
Designed for 1 unit of whole blood Filter volume 450ml.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
High post-filtration whole blood volume recovery rate >91%
Consistent flow rate
Specifications
Product Ref. No. |
WB Filter FBWB450-HE10 |
Designed for |
1 unit of WB volume 450ml |
Type |
In-line use |
Special feature |
Warm blood filtration |
Filtration Efficiency level(Residual leukocyte /unit) |
< 1x106) |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate (PC) |
Priming volume (ml) |
40ml |
PLT Filter FIRC100-SE10
PLT Filter
PLT filter Supplier
Designed for 1 unit of platelet rich plasma from 450~500ml of whole blood. Features
Designed for 1 unit of platelet rich plasma from 450~500ml of whole blood.
Warm blood filtration, the filtration can be proceeded immediately after the donation.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
The platelet recovery rate not less than 85%
Consistent flow rate
PLT Filter FBPL01K-HE00
PLT Filter
PLT filter Supplier
Features
Designed for 5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
The platelet recovery rate not less than 85%
Consistent flow rate
Specifications
Product Ref. No. |
FIPL01K-HE00 |
Designed for |
5~6 units manual collection of platelet or one unit of machine collection of platelet at hospital |
Type |
For red cell bed side or laboratory use |
Special feature |
Blood should leave the body for at least 4 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x106 |
Housing |
Hard |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polycarbonate or Acrylonitrile Butadiene Styrene plastic |
(PC / ABS) |
|
Priming volume (ml) |
11ml |
RBCs Filter FIBC450-SE10
RBCs Filter
RBCs filters Manufacturer, red blood cell filter wholesaler
Designed for 1 unit of RBC suspension from 450/500ml of whole blood. Features
Designed for 1 unit of RBC suspension from 450/500ml of whole blood.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
Post-filtration RBC recovery rate not less than 90%
Consistent flow rate
RBCs Filter FIPP450-SE10
RBCs Filter
Leukocyte Reduction Filter
RBCs filters Manufacturer, red blood cell filter wholesaler
Designed for 1 unit of RBC suspension from 450/500ml of whole blood. Features
Designed for 1 unit of RBC suspension from 450/500ml of whole blood.
High efficiency leukocyte reduction filter (Residual leukocytes <1x106)
Post-filtration RBC recovery rate not less than 88%
Consistent flow rate
Specifications
Product Ref. No. |
FIPP450-SE10 |
Designed for |
1 unit of RBC suspension from 450/500ml of whole blood |
Type |
In-line use |
Separation way |
For PRP way |
Special feature |
Blood should leave the body for at least 4 hours |
Filtration Efficiency level (Residual leukocytes /unit) |
< 1x106 |
Housing |
Soft |
Membrane material |
Non-woven polyester (surface modified) |
Housing material |
Polyvinyl chloride (PVC) |
Priming volume (ml) |
35ml |