IVY METERING CO.,LTD

IVY METERING CO.,LTD

Company Product

  • G3 PLCl Meter
  • Brief Introduction

    D114011-X929011 is a single phase two wire Din rail prepaid meter with G3 PLC communication and built-in relay, it can be used with keypad IHD (optional).

    1P Din Rail Meter Technical Parameter

    Part number

    D114011 - X9029011

    Ref. voltage

    230V

    Ref. current

    5(80)A

    Impulse constant

    1000imp/kWh

    LCD display

    W/O

    Operation temp.

    -20~+70℃

    Storage temp.

    /

    Relative humidity

    ≤95%

    Ref. frequency

    50Hz

    Accuracy class

    Starting current

    Flashing red

    Impulse indication,width = 80ms±20ms

    Power consumption

    ≤ 2W,<10VA

    Standard compliant

    IEC62052-11, IEC62053-21, IEC62055-41

     

    Metering Function

    Measuring Devices meter Maximum current is up to 80A

    Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1 month, MD of last 2 month, the absolute value of total active energy, the absolute value of total active tariff energy, total input energy of the current month, total input energy of last 5 month, total output energy of the current month, total output energy of last 5 month, and total reactive energy.

    Communication Function

    Support G3 PLC communication

    Support IR communication

     Din Rail Meter wholesale Buzzer Function

    with buzzer inside, it will beep when low credit for 5 seconds, and you could press any key to turn it off. Also you could configure to enable or disable this buzzer function by IR communication.

    Tariff

    Divide into weekday timetable and weekend timetable, with 8 time period and 8 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time.Measuring Devices meter manufacturer will automatically switch the tariff table at the switching time.

    Others

    Support load ground connection, switch detection, influence of external magnetic field, abnormal voltage record.

    Degree of protection: IP51 (indoor meter)

  • Send Inquiry
  • Kwh Meter
  • Kwh Meter

    1. Brief Introduction

    DTSY-T01 is a single phase din-rail meter two wire split type prepayment keypad meter approved by STS. It can access to any STS standard 100A relay which can trip when over load or balance run Din Rail Meter consist of Measurement and Control Unit (MCU) and Customer Interface Unit (CIU). MCU achieve data exchange with CIU through non polarity twisted pair cable and meanwhile supply power to CIU, CIU need not external , customer can check the information in home and realize remote or SMS recharge.

    1. Technical Parameter of 1P Din Rail Meter

     

    Ref. voltage

    230V±20%

    Ref. current

    5(80)A

    Impulse constant

    1000imp/kWh

    LCD display

    LCD6+2

    Operation temp.

    -20~+70℃

    Storage temp.

    /

    Relative humidity

    95%

    Average relative humidity

    75%

    Accuracy class

    Starting current

    Ref. frequency

    50Hz

    Power consumption

    ≤ 1W,≤8VA

    Standard compliant

    IEC62052-11,IEC62053-21,IEC62056-21,IEC62055-41

    1. Function Description

       Metering Function

    This single phase split prepayment meter is based on virtual medium. The data encryption process complies with international standard IEC62055 and certified by STS association.

    Communication Function

     IR communication interface in MCU can set and read local parameter.

     MCU support IR and non polar twisted pair cable communication, IR complies to IEC62056-21(A) mode, protocol of non polar twisted pair cable is DLT645-2007.

     IR :Baud rate:2400, 7 data bits,1 even,1 stop bit.

    RS485 : Baud rate :9600,8 data bits,no even,1 stop bit.

    Prepayment Function

    3. Recharge

    After purchasing the credit, user will get a recharge token, enter 20 digits token through keypad, the token will scroll display from right to left. The interval typing time should within 20S. Type " clear button " to modify entering error. After confirmed, press “Enter”. If don’t type completely, the type operation is invalid.

    Enter through two modes: Keypad or token is accepted, CIU will display success or error code.

    Error code:

    Err 11:Returned data from MCU is invalid

    Err 29 : The command can’t clear cover open event. Err 31 : Keypad testing(unused)

    Err 32 : Display tampering state.(unused) Err 33 : Display current power(unused) Err 34 : Display phase unbalance(unused) Err 35 : Reserved

    Err 36 : Reserved Err 40 : Reserved Err 41: Alien data

    Err 42 : Banned data.

    Err 43 : Used data Err 44 : Expired data Err 45 : expired Key

    Err 46 : Power set exceed range

    Err 47 : The mode is not allowed to purchase credit Err 48 : Inconformity to key modify process

    Err 49 : The data is not used by meter Err 50 : The data is before produce.

    Err 51 : Numerical value error. Err 52 : Special use data

    Err 53 : Key set over time.

    Err 54 : Manufacturer No. error. Err 55 : Reserved 2

    Err 56 : Reserved 3

    Err 57 : Inconformity to key modify process,meter key type uninitialized. Err 58 : Inconformity to key modify process,meter key initialize set error.

    Err 59 : Balance exceed allowed regrate energy,this recharge invalid. Success code:

    Good 01 :Key modify Token 1 decoding success(enter Token 1 first)

    Good 02 :Key modify Token2 decoding success(enter Token 2 first)

    Good 28 :Clear cover open state success. Good 88 :Recharging success

    Good 81 :Set power threshold success. Good 82 :Clear remain energy success. Good 83 :Clear event record success. Good 84 :Key modify success.

    Good 85 :Key modify and clear TID success Good 70 :Alarm dwell time set success

    Good 71 :Energy alarm threshold set success Good 73 :CIU backlight time set success Good 75 :CIU ID set success

    Good 90 :Perform all testing Good 91 :Relay testing Good 92 :LCD testing

    Good 93 :Display total energy Good 94 :Display Krn

    Good 95 :Display Ti

    Good 96 :Display power threshold Good 97 :Display software version

    3. Management Code

    (1)General management TOKEN:

    This function supplied by STS vending system which used to test meter performance and check parameter information. This management code without STS encryption. It can operate for every prepayment meter which complies with STS protocol. Main function includes relay testing, LCD testing, and display total energy, key version number, tariff type, power threshold, software version number.

    (2)Special management TOKEN:

    This key is encrypted by STS protocol, includes time and relevant manage information. It is only used for the meters that have the same key. Main functions: set maximum power, clear balance credit, modify key, clear events.

    (3)Set power limit:

    Enter token for setting power limit to meter, the meter will display the value if set successful. The unit of Token is W, display format is kW, the default value is kW. The Maximum value is 65535W. LCD will show “Good 81” after set successfully.

    (4)Clear the remain credit:

    Enter token for clearing remain credit, then press enter button, LCD will show" Good 82 " .

    (5)Modify the key:

    Enter two TOKEN without sequential difference. After entering the first TOKEN, the second must be entered within 180s. LCD will show “Good 01” if the first TOKEN is successful, show "Good 84" if the second TOKEN is successful. If enter second TOKEN first, LCD will show "Good 02", then enter the first TOKEN, LCD will display "Good84". And if clear TID at the same time, LCD will show "Good85" after modify successfully.

    (6)Clear event records:

    Enter token for clear event to meter then clear all events records and signs. LCD display “Good83”

    (7)Prevent credit hoard:

    Meter has a preset hoard preventing value. The total energy in the meter cannot exceed this value, or the TOKEN cannot be recharged. This TOKEN can be used once the hoard condition is not satisfied. The default value is .

    (8)Overload process

    If the over load exceeds for more than 45s, the relay opens and the relay indicator on display lights. The relay closes again after 150s, and the indicator goes out.

    If the above situation happens for more than 5 times in 30 minutes, the relay will close again after 45 minutes. If the times does not reach 5 (eg. 4 times) in 30 minutes, the recover time of the relay is still 150s, and this 4 times’ record will be cleared if this situation not happen in next 30 minutes. The over load value could be set through keypad or PC software.

    (9)Balanced credit alarm

    This Measuring Devices meter has the function of 1 degree credit balance alarm. The limit can be set through code or communication. The red LED flashes and the buzzer alarms if the credit balance is less than the limitation. Press any button can clear the alarm, but it will alarm again after a period of delay, this delay period can also be set through code or communication. After all the credit used up,the relay opens and LED goes out.

    Overload Function

    Overload trip, threshold power programmable.

    Keypad Function

    Keypad on CIU can enter recharge token and check meter parameter.

    Event Log Function

    Last 50 times recharge token code

    Last 50 times recharge credit

    Total recharge times

    Over power trip times

    Cover open times

    Power failure times

    Technical TOKEN used times

    Power reverse times

    Note:Above events total times not exceed 60000

    Others

    MCU built-in 100A latching relay

    Din Rail Meter keeps last 50 recharge records and relevant token to inquire.

    Prepaid function: recharge, management

     

  • Send Inquiry
  • AC Digital Meter
  •  AC Digital Meter

    1. Brief Introduction  

    DTSF/U353 is a three phases four wires digital energy meter with current transformer, LCD backlight, IR & RS485 communication ( protocol EN62056:IEC1107 & DLT645:2007 ) and tariff, which can measure and record the active energy consumption of load in 50Hz single phase AC power grid

    1. Technical Parameter of 3P Din Rail Meter

    Ref. voltage

    3*220/380V

    Ref. current

    3*(6)A

    Impulse constant

    12000imp/kWh

    LCD display

    LCD5+3

    Operation temp.

    -20~+70℃

    Storage temp.

    -40~+80℃

    Relative humidity

    ≤90%

    Ref. frequency

    50Hz

    Accuracy class

    Starting current

    ()

    Creeping

    Anti-creep logistic design

    Power consumption

    ≤ 2W,<10VA

    Standard compliant

    Performance test: GB/T GB/T

    Protection degree: GB/T20138-2006

     

    1. Function Description

    Din Rail Energy Digital Meter Metering Function

    Active & reactive energy, forward & reverse measurement

    3 elements settable (positive,positive+negative,positive-negative)

    CT ratio range: 5:5 ~7500:5

    (5:5,40:5,50:5,60:5,75:5,100:5,125:5,150:5,200:5,250:5,300:5,400:5,500:5,600:5,800:5,1000:

    5,1250:5,1500:5,2000:5,2500:5,3000:5,4000:5,5000:5,6000:5,7500:5)

    5:5----40:5        LCD=5+3;

    50:5----300:5     LCD=6+2;

    400:5----3000:5  LCD=7+1;

    4000:5----7500:5  LCD=8+0;

    Support max demand

    Support resetting energy

    Support setting holiday tariff & weekend tariff

    Communication Function

    Support IR communication, EN62056 (IEC1107) protocol

    RS485 Communication, DLT 645:2007 protocol

    Measuring Devices meter wholesale Display Function

    Displaying total energy, tariff energy, 3 phases voltage, 3 phases current, power, apparent power, power factor, frequency, demand, ct ratio, impulse output, communication address etc.

    Plz refer to LCD display part

    Keypad Function

    Selecting display content, setting CT ratio, LCD scrolling period and resetting energy & backlight type via 2 keypads.

    Setting content of automatic scrolling mode via IR

    Backlight Display

    Support 3 types of displaying can be set via keypads:

    Selecting lighting when pressing the key / normal bright / normal dimmed

    Din Rail Meter Impulse Output

    Support 4 types of impulse output method via communication:

    Selecting 12000 / 1200 / 120 / 12

  • Send Inquiry
  • Suspension Meter
    1. Brief Introduction  

    D129022 is a single phase two wires suspension type energy meter with 60A latching relay, LCD display, FIR & RS485 communication (protocol DLT645:2007), monthly and daily electricity consumption storage.

    Parameter of Multi-Rate Energy Meter

    Ref. voltage

    220V

    Ref. current

    10(60)A

    Impulse constant

    1600imp/kWh

    LCD display

    LCD5+1

    Temp. range

    -40~+70℃

    Annual average humidity

    75%

    Max humidity

    95%

    Ref. frequency

    50Hz

    Accuracy class

    Cl. (Active)

    Starting current

    ( Cl. )

    Suspension Meter wholesale Power consumption

    ≤ 

    Standard compliant

    IEC62053-21,IEC62052-11,IEC62053-23

     

    1. Function Description of 1P Suspension Meter

    Metering Function

    Active energy measurement

    Communication Function

    Support RS485 Communication, DLT 645:2007 protocol with baud rate 2400.

    Support FIR communication, the interface is used for reading and setting local parameters.

    Display Function

    Plz refer to LCD display part

    Button Function

     LCD scrolling pages through the button

    Others

     Built-in 60A latching relay

  • Send Inquiry
  • AMI Meter
  • AMI Meter

    1. Brief Introduction                                                     

    This is one of latest AMI system solution which combines almost all kinds of wireless communication, including Zigbee, PLC, GPRS and Wifi. IVY provides you the whole solution including smart meter, DCU and AMI system. It integrates remote reading, control and analysis function. This is the answer to your specific needs: from the reliable commercial meter to the complex measuring device with comprehensive additional functionality for advanced data acquisition and flexible tariff control.

    Parameter  1P Suspension Meter

    Parameter

    Characteristic

    Meter Type

    Single phase smart meter

    Wiring

    Single phase 2 wire

    Accuracy

    Active , reactive

    Operating voltage

    230+/-10%

    Rated current

    5(45)/5(100)

    Rated frequency

    50Hz

    Power consumption

    Communication Int.

    Infrared, RS485, PLC, Zigbee, GPRS

    Technical standard

    IEC62052-11:2003, IEC62053-21:2003, IEC62053-22: 2003, IEC62053-23:2003

    DLMS/COSEM

    Suspension Meter Working environment

    Normal operating temp:-10℃~+55℃

    ℃~+60℃

    Storage&transport temp. -25℃~+75℃

    Storage&operating humidity: <95%

    Protection

    IP54

    Overall dimension

    **71mm

    1. Function Description Measuring Devices

    Additional auxiliary power supply to assure data reading during power down phases

    Power quality monitoring functions with alarm and log features

    Real-time alarm system

    Measure and display current date and time; kWh; kvarh; Maximum kW and kvar demand; Cumulative kW and kvar demand; Instantaneous active and reactive power; Instantaneous voltage current and power factor.

    Time of use metering: the smart meter can be programmable to record import and export energies (kWh and kvarh) and import and export demand (kW and kvar) on different rates.

    Load profile function: the smart meter is able to record 15-minute three decimal points load profile data with 4 channels consisting total import kW, total import kvar and total export kvar demand.

    Measuring Devices meter registration: the smart meter can be registered with Data Concentrator Unit (DCU) of AMI Central System(consisting of Meter Data Management System (MDMS). Head End System and relevant systems and accessories) automatically.

    Automatic meter reading: the smart meter can transmit measured quantities to DCU or AMI system automatically.

    Remote load disconnect and reconnect: the smart meter has a remotely controllable disconnect/reconnect switch for supporting load limiting, load shedding and prepayment function.

    Tamper detection: the smart meter can detect and record attempted tampering event and also show alarm signal on LCD. And the tempering events can be sent to AMI system automatically.

    Prepayment function: the smart meter also support on-line prepayment function programmed remotely from AMI system and from local communication.

    Power outage monitoring: the smart meter can detect power outage and power restoration and record as an event.

    Meter registration: the smart meter can be registered with Data Concentrator Unit(DCU) of AMI Central System (consisting of Meter Data Management System (MDMS). Head End System and relevant systems and accessories) automatically.

    Automatic meter reading: the smart meter can transmit measured quantities to DCU or AMI system automatically.

    Remote load disconnect and reconnect: the smart Din Rail Meter has a remotely controllable disconnect/reconnect switch for supporting load limiting, load shedding and prepayment function.

    Tamper detection: the smart meter can detect and record attempted tampering event and also show alarm signal on LCD. And the tempering events can be sent to AMI system automatically.

     Prepayment function: the smart meter also support on-line prepayment function programmed remotely from AMI system and from local communication.

    Power outage monitoring: the smart meter can detect power outage and power restoration and record as an event.

  • Send Inquiry
  • Keypad Meter
  • Keypad Meter

    1. Brief Introduction                                                       

    This is a three phases four wires prepayment keypad split type meter, which is based on virtual medium, the data encryption process complies with international standard IEC62055.

    Built-in 100A relay in MCU which can trip when over load, balance run out, tamper happen and so on.

    RF communication between MCU and CIU, so user can recharge or check balance at home from CIU conveniently, and CIU will display MCU’s real time data for user.

    Parameter  3P Suspension Meter

     

    Ref. voltage

    3*230/400V

    Ref. current

    10(100)A

    Impulse constant

    1000imp/kWh

    LCD display

    LCD6+2

    Temp. range

    -25~+70℃

    Relative humidity

    <90%

    Ref. frequency

    50Hz

    Accuracy class

    Starting current

    Power consumption

    ≤ 1W, <8VA

    Standard compliant

    Performance test: GB/T GB/T

    Protection degree: GB/T20138-2006IEC62052-11,IEC62053-21,IEC62056-21,IEC62055-41

     

    1. Function Description 3 Phase Smart Meter

    Build in 100A relay which can trip when over load, power limit programmable.

    Cover open detection.

    Keypad on meter which can enter recharge token and check meter parameters.

    Supports phase sequence detection, phase angle measurement, quadrant judgment etc.

    Supports harmonic percentage measurement for voltage and current, it can used for energy quality analysis.

    keypad meter wholesale keeps last 50 recharge records and relevant token for query.

    With Infrared for local reading and setting.

    With RF wire communication between MCU and CIU, CIU can display balance, alarm time and so on events. Enter short key in CIU keypad to read MCU’s data, enter recharge token in CIU keypad to recharge for MCU.

    Battery backup for CIU if power off.

  • Send Inquiry
  •  Concentrator
  • Concentrator

    1. Brief Introduction                                                      

    This is a GPRS version concentrator that receives the real-time tasks issued by the main station through GPRS. At the same time, it periodically reads the measurement data of the metering device and uploads it to the main station, and it can receive the data actively uploaded by the meter through Lora and upload it to the cloud.

    2.Concentrator Converter Technical Parameter  

    Reference voltage

    220V±20%

    Related frequency

    50Hz-60Hz

    Communication

    Up: GPRS

    Down: Lora

    LoRa baud rate

    438MHz

    WIFI

    IEEE ()1-13

    1. Concentrator Converter wholesale Function Description                                                    

    Regular read the data with 15 minutes , then send the data to server together

    Communication with meter by RS485, communication with server /front-end processor by GPRS  

    Support remotely update

  • Send Inquiry
  • DCU
  •  DCU

    1. Brief Introduction                                                      

    J119005 is a concentrator which can read and reserve device data via Ethernet according to master station’s command, and actively upload and reserve data which collected from collector.

    1. Concentrator Converter wholesaleTechnical Parameter

    Reference voltage

    220V±20%

    Related frequency

    50Hz-60Hz

    Net

    do not support AUTO MDI/MDIX

    self-adaption Ethernet port

    Baudrate

    115200

    WIFI

    IEEE ()1-13

    1. Concentrator Converter manufacturerFunction Description   

    Reading the data with 15 minutes , then send the data to server together

    Read meter data every 15 seconds from collector, and send to HES;

    Read meter demand data every 15 seconds. If the communication between system and HES is broken, can use this data to fill in the vacancy;

    Communication between upside device (HES, Cloud) and downside device (collector) via Internet.

    dcu meter Able to visit random level device;

    Able to connect with many device (more than one collector, HES, Cloud) 

  • Send Inquiry
  • CT PT VT Meter
    1. Brief Introduction                                                      

    This is a three phases DLMS multifunctional energy meter which was warmly welcomed in South-American due to standard installation. It equipped RS485, IR, RF etc communication method, four tariffs, relay optional and CTT certificate.

    1. three Phase Energy MeterTechnical Parameter  

    Ref. voltage

    3*120/208V 3*127/220VAC

     

    Ref. current

    5(100)A

    Impulse constant

    6400imp/kWh

    Ref. frequency

    60Hz

    Accuracy class

    Communication

    RS485 DLMS protocol

    LCD display

    6+2

    Starting current

    ()

    Power consumption

    Voltage circuit:<2W/<10VA ; Current circuit:<

    Protection level

    IP54

    Anti-UV rating

    V3Flame retardant rating V2

     

    1. DLMS Meter manufacturerFunction Description                                                     

    The meter can display voltage, current, active power, reactive power, date and time on the LCD display.

    Active and reactive power measurement, bidirectional measurement, input power and output power, instantaneous power

     Built-in 100A relay controls the opening and closing of the meter through communication

    Support RS485, IR communication (DLMS) and RF communication (custom)

    RS485: Baud rate 9600 (fixed), 8-bit data. Parity check. One stop bit

     IR: baud rate 9600 (fixed), 8-bit data, parity, one stop bit

    RF: Baud rate 9600 (fixed), 8-bit data, no parity. One stop bit

    RF communication is only for home display

     Load the configuration file for 15 minutes for 6 months

    ct pt vt meter wholesale Anti-stealing function: through accurate measurement and alarm (must send alarm signal through RS485 interface)l 

    Other alarms: relay disconnection, over-voltage, buck, reverse, power off

    FW upgrade through RS485 communication interface

     Event record: over voltage, low voltage, terminal cover open (open cover detection), password change, etc.

     Local (IR) and remote upgrade (RS485)

    No need to change the password by button

     

  • Send Inquiry
  • DLMS Relay
    1. Brief Introduction                                                       

    This is a three phases DLMS multifunctional energy meter which was warmly welcomed in

    South-American due to standard installation. It equipped RS485, IR, RF etc communication

    method, four tariffs, relay optional.

    2.DLMS Meter Technical Parameter       

    Ref. voltage

    220V

    Ref. current

    5(100)A

    Impulse constant

    1000imp/kWh

    Ref. frequency

    50Hz

    Accuracy class

    Cl.

    Communication

    RS485 DLMS protocol

    1. Measuring Devices meterFunction Description                                                   

    Two elements

    Measure voltage,current,power consumption

    Multi-tariff

     

  • Send Inquiry
  • NB-IOT Meter
  • NB-IOT Meter

    1. Introduction                                                             

    is a three phases four wires intelligent sensor device with WIFI、RS485 communication, which integrates functions such as information collection, real -time monitoring, analysis prediction, security alarm, energy consumption monitoring, and remote management and control.IOT WIFI Din Rail Meter is widely used in various types electrical appliances and electromechanical equipment to effectively achieve long-distance interconnection, security prevention and control, fault prediction and prevention. Maintenance, energy saving and consumption reduction.

    2 NB IOT meter Technical Parameter    

    Voltage:

    3*180~240V

    Current:

    5(80)A

    Frequency:

    50-60Hz

    Accuracy class:

    1

    Standard:

    IEC62052-11、IEC62053-21

    Starting current:

    Power consumption:

    ≦10VA

    Impulse constant:

    1000imp/kWh

    Installation:

    Din-rail

    Temperature range:

    -20~70℃

    Average humidity:

    ≦75%

    IOT WIFI Triphase Meter NW:

    Dimensions:

    100*76*65mm

    Communication:

    WIFI/RS485

                

  • Send Inquiry
  • Smart Sensor Manufacturer
  •  Smart Sensor Manufacturer

    1. Introduction                                                             

    is a single phase smart sensor with WIFI & RS485 communication,including information collection , real-time monitoring,energy consumption monitoring,alarming function ,remote control and management, which could be widely used in electrical appliance、electromechanical device

    2 multifunctional sensor Technical Parameter        

    Voltage:

     180~240V

    Current:

     5(100)A

    Frequency:

     50-60Hz

    Accuracy class:

    1

    Standard:

      IEC62052-11、IEC62053-21

    Starting current:

      

    Power consumption:

      ≦10VA

    Impulse constant:

      1000imp/kWh

    Installation:

      Din-rail

    Temperature range:

      -20~70℃

    Average humidity:

      ≦75%

    IOT Meter NW:

      

    Dimensions:

      90*18*72mm

    Communication:

      WIFI/RS485

     

  • Send Inquiry
  • 1 Phase Smart Sensor
  • 1 Phase Smart Sensor

    1. Introduction                                                             

    is a single phase smart sensor with WIFI & RS485 communication, switch control, energy measurement...

    1. IOT Multifunctional Smart Sensor MeterTechnical Parameter   

    Voltage:

    220V

    Current:

    5(80)A

    Frequency:

    50-60Hz

    Accuracy class:

    1

    Standard:

    IEC62052-11、IEC62053-21

    Starting current:

    Power consumption:

    ≦10VA

    Impulse constant:

    1000imp/kWh

    Installation:

     Din-rail

    Temperature range:

    -20~70℃

    Average humidity:

    ≦75%

    Smart Sensor  NW:

    /

    Dimensions:

    90*36*72mm

    Communication:

    WIFI/RS485

  • Send Inquiry
  • GPRS Socket
  • GPRS Socket

    1. Brief Introduction                                                     

    ZD159011 is a cost-effective intelligent socket .It could support bluetooth and GPRS communication, Which can achieve reading data remotely with concentrator. According to the design of standard type 86, it has the characteristics of small size, light weight, beautiful appearance and easy installation.

    1. Technical Parameter        

    Function

    gprs contrator  could support bluetooth and GPRS communication. The mobile APP can connect socket via bluetooth to read and use energy data .It could upload data directly/save date to sever .

    It could measure active/reactive energy,current,voltage,active power,reactive power ,apparent power , frequency, power factor .

    smart socket meter could collect current, voltage,starting current waveforms, and detect harmonic content of current and voltage .

    It has built-in 10A control relay .

    Technical Parameters       

    Rated voltage

    220V

    Current

    2(10)A

    Accuracy class

    Class 1

    Standard

    IEC62052-11, IEC62053-21

    Frequency

    50-60Hz

    Pulse constant

    3200Imp/kWh

    Power consumption

    ≤10VA  ≤1W

    Starting current

    Temperature range

    -20~70℃

    Average relative humidity

    75%

    95%

     

  • Send Inquiry
  • PLC Socket
  • PLC Socket

    1. Brief Introduction                                                     

    ZQ0B5001 is a cost-effective intelligent socket .It could support bluetooth and PLC communication, Which can achieve reading data remotely with concentrator. According to the design of standard type 86, it has the characteristics of small size, light weight, beautiful appearance and easy installation.

    1. Technical Parameter                                                   

    smart socket meter  Function

    plc Socket wholesale could support bluetooth and PLC communication. The mobile APP can connect socket via bluetooth to read and use energy data .It could upload data directly/save date to sever via PLC concentrator .

    It could measure active /reactive energy,current,voltage,active power,reactive power ,apparent power ,frequency,power factor.

    plc Socket manufacturer could collect current, voltage, starting current waveforms, and detect harmonic content of current and voltage .

    It has bulit-in 10A control relay .

    Technical Parameters

    Rated voltage

    220V

    Current

    2(10)A

    Accuracy class

    Class 1

    Standard

    IEC62052-11, IEC62053-21

    Frequency

    50-60Hz

    Pulse constant

    3200Imp/kWh

    Power consumption

    ≤10VA  ≤1W

    Starting current

    Temperature range

    -20~70℃

    Average relative humidity

    75%

    95%

  • Send Inquiry
  • Smart Socket
  • Smart Socket

    1. Brief Introduction                                                     

    This is a new cost-effective intelligent socket. It has many functions, as below: 

    Real-time, accurate reading and collection of energy, power, current, voltage, temperature and other electrical parameters of the device. 

     Real-time monitoring of the use of electrical equipment, over-current, overload, over-temperature and other abnormal safety warnings, dangerous cut-off protection.

     Support charging and charging of electrical equipment, timing management, support charging timing& payment management by system.

    1. smart socket meterTechnical Parameter              

    Rated voltage

    220V

    Current

    2(10)A

    Accuracy class

    Class 1

    Standard

    IEC62052-11, IEC62053-21

    Frequency

    50-60Hz

    Pulse constant

    1000Imp/kWh

    Power consumption

    ≤10VA  ≤1W

    Starting current

    Temperature range 

    -20~70℃

    Average relative humidity

    75%

    95%

  • Send Inquiry
  • Fire Detector
  • Fire Detector

    1. Brief Introduction                                                        

    This is a multi-way multifunctional intelligent safety monitoring device. Wire temperature & electric leakage & energy consumption can be monitored in real time. The data can be uploaded regularly, and the abnormal situation could be alarmed timely. It could help the users better manage regional electricity security.

    2.fire detector meter Technical Parameter    

    Auxiliary power supply range

    96~265VAC

    Standard

    GB GB

    Frequency

    50Hz

    Power consumption

    ≤8VA ≤

    Temperature detection range

    -50~150℃

    Leakage detection range

    20~1000mA

    Optional residual current transformer

    0~100A(2000:1)

    0~400A(2000:1)

    Display

    Temperature  LCD3+1

    Leakage  LCD1+3

    Equipment working temperature range

    -20~70℃

    Average relative humidity

    75%

    Max. humidity

    95%

    1. fire detector meter supplierFunction Description                                                    

    4 ways temperature measurement

    1 way remaining current detection

    LCD could display current wire temperature & electric leakage,and indicate the alarm situation(normal: blue; alarm: red)

    LED status(normal: always-on; alarm: blink)

    Relay control output(: 5A 250VAC)

    RS485 communication protocol: bus support remote upgrade .

    Communication could read temperature&remaining current;relay 5A could control switch

    Notes:The leak current ‘s alarm function could stop when the threshold will be 0mA of remaining current. The LCD display will be red color when there will be leakage alarm .

  • Send Inquiry
  • Smart Switch
  • Smart Switch

    1. Brief Introduction                                                      

    This is a single multifunctional smart electrical safe monitoring equipment. Real-time monitoring of wire temperature and leakage conditions. Upload date regularly, real-time monitoring energy, abnormal conditions ,timely alarm.

    1. Intelligent Switch meterTechnical Parameter      

     

    Auxiliary power supply range

    175~265VAC

    Standard

    GB  GB

    Frequency

    50Hz

     

    Consumption

    ≤8VA

    Temperature range

    -50~150℃

    Leakage range

    20~1000mA

    Intelligent Switch CT

    0~100A(2000:1)

    Display

    Temperature

    LCD3+1

     

    Leakage

    LCD1+3

    Operating temperature range

    -20~70℃

    Average relative humidity

    75%

     

    Max. humidity

    95%

     

    1. Smart SwitchmeterFunction Description                                                    

     One way temperature measurement

     One way after current detection

     LCD could display the current wire temperature and leakage current value

     Backlight & LED three-color indicators(normal: green, fault: yellow, alarm: red)

     Buzzer alarm when fault & alarm prompts

     RS485 communication, communication protocol will be bus

     Support remote upgrade

  • Send Inquiry
  • Power Sensor
  • Power Sensor

    1. Brief Introduction                                                     

    Overview

    The multifunctional power sensor ES730T, adopts advanced ultra-low power large-scale integrated circuit technology and high-tech products manufactured by SMT process. The key components are long-life components of international well-known brands to improve reliability and life of the combined electric fire sensor ES730T is composed of safety monitoring unit and metering unit with RS485/NB communication function. In the safety monitoring, the built-in current transformer is used to monitor the remaining current, and the built-in temperature sensor is used to monitor the wire temperature. The meter has the advantages of high measurement accuracy, good stability, strong overload capacity and high reliability, widely used for monitoring & measuring safety parameters .

    Fire Detector Standards

    Complied with standards:

    electrical fire monitoring system-part 2: residual current electrical fire monitoring detector

    electrical fire monitoring system part 3 Temperature-measuring electric fire detector

    IEC 62052 - 11 - 2003 electric measuring instrument. General requirements, test and test conditions-part 11 measuring instruments

    IEC 62052 - 21 - 2004 Electric quantity measuring equipment (AC) General requirements, tests and test conditions. Part 21: tariff and load control equipment

     

  • Send Inquiry
  •  Smart Sensor
  •  Smart Sensor

    1. Brief Introduction                                                     

    Overview

    The multifunctional power sensor ES210T,adopts advanced ultra-low power large-scale integrated circuit technology and high-tech products manufactured by SMT process. The key components are long-life components of international well-known brands to improve reliability and life of the combined electric fire detector ES210T is composed of safety monitoring unit and metering unit with RS485 communication function. In the safety monitoring, the built-in current transformer is used to monitor the remaining current, and the built-in temperature sensor is used to monitor the wire temperature. The meter has the advantages of high measurement accuracy, good stability, strong overload capacity and high reliability, widely used for monitoring & measuring safety parameters .

     multifunctional sensor Standards

    Complied with standards:

    electrical fire monitoring system-part 2: residual current electrical fire monitoring detector

    electrical fire monitoring system part 3 Temperature-measuring electric fire detector

    IEC 62052 - 11 - 2003 electric measuring instrument. General requirements, test and test conditions-part 11 measuring instruments

    IEC 62052 - 21 - 2004 Electric quantity measuring equipment (AC) General requirements, tests and test conditions. Part 21: tariff and load control equipment

    1. Fire DetectorBasic Functions                                                         

    Metering & Monitoring

    The multifunctional power sensor can measure, record and display the remaining current, wire temperature and other safety parameters of the circuit of the current equipment, as well as the operating parameters such as power, voltage, current, power factor and so on.

    LED & Backlight Indication

    The multifunctional sensor manufacturer uses three bright & long-life LED indicators with the following backlight display panel functions:

    -Relay indicator: red, which lights up only when the contacts of relay are closed .

    -Pulse indicator: flashes when the device is running at the load end, flashes more frequently with the greater the total power of the device, and does not flash when there is no load.

    -Backlight indicator: green, working properly; yellow, alarm event; red, alarm trip event

  • Send Inquiry