Shanghai Xingliao Trading Co.,Ltd.

Shanghai Xingliao Trading Co.,Ltd.

Company Product

  • Double Blood Bag
  • Blood Transfusion System

    Standard Blood Bag

    Fosmedic Blood bag is designed for blood collection,Processingand transfusion of whole blood.

    Fosmedic Double Blood Bag is designed for whole blood collection and separation of whole blood into two different components;

    Red blood cells and plasma. This is obtained through the process of centrifugation and extraction.

    The primary bag contains CPDA-1 anticoagulant solution.

    Technical Details

    Product

    Double Blood Bag

    Film Material

    Blow extruded Or Roll welding

    Primary Bags

    The volume is optional

    Needle Gauge

    16G

    Solution

    CPDA 1

    Certificate

    GMP, CE, ISO13485

    Sterilization

    Steam sterilization

    Shelf Life

    2 years

    Model:Code:D250,D350,D450,D500

    Optional: 1. Sampling Pouch,2. Sampling port,3. Needle Protector

  • Send Inquiry
  • Quadruple Blood Bag
  • Blood Transfusion System

    Standard Blood Bag

    Fosmedic Blood bag is designed for blood collection,Processing and transfusion of whole blood.

    Fosmedic Quadruple Blood Bag is designed for whole blood collection and separation of whole blood into four different components;

    Red blood cells, plasma, platelets and cryoprecipitate or leukocyte through the process of centrifugation and extraction.

    Technical Details

    Product

    Quadruple Blood Bag

    Film Material

    Blow extruded Or Roll welding

    Primary Bags

    The volume is optional

    Needle Gauge

    16G

    Solution

    CPDA 1 OR CPD-SAGM

    Certificate

    GMP, CE, ISO13485

    Sterilization

    Steam sterilization

    Shelf Life

    2 years

    Model:Code:Q250,Q350,Q450,Q500

    Optional: 1. Sampling Pouch,2. Sampling port,3. Needle Protector,4.Platelet Storage Bag,5.Leukocyte Filter

  • Send Inquiry
  • Single Blood Bag
  • Blood Transfusion System

    Standard Blood Bag

     

    Fosmedic Blood bag is designed for blood collection,processing and transfusion of whole blood.

    The primary bag contains CPDA-1 anticoagulant solution.

    Technical Details

    Product

    Single Blood Bag

    Film Material

    Blow extruded Or Roll welding

    Primary Bags

    The volume is optional

    Needle Gauge

    16G

    Solution

    CPDA-1

    Certificate

    GMP, CE, ISO13485

    Sterilization

    Steam sterilization

    Shelf Life

    2 years

    ModelCode : S250,S350,S450,S500

    Optional: 1. Sampling Pouch,2. Sampling port,3. Needle Protector

  • Send Inquiry
  • Triple Blood Bag
  • Blood Transfusion System

    Standard Blood Bag

    Fosmedic Blood bag is designed for blood collection,Processing and transfusion of whole blood.

    Fosmedic Triple Blood Bag is designed to separate whole blood into three blood components;

    Red blood cells, platelets and plasma through the process of centrifugation and extraction

    Technical Details

    Product

    Triple Blood Bag

    Film Material

    Blow extruded Or Roll welding

    Primary Bags

    The volume is optional

    Satellite Bags

    16G

    Needle Gauge

    CPDA 1 or CPD-SAGM

    Solution

    GMP, CE, ISO13485

    Sterilization

    Steam sterilization

    Shelf Life

    2 years

    Model Code: D250,D350,D450,D500

    Optional:1. Sampling Pouch,2. Sampling port,3. Needle Protector,4.Platelet Storage Bag,5.Leukocyte Filter

  • Send Inquiry
  • T&B TRIPLE BLOOD BAG
  • T&B Blood Bag System

    For whole blood collection and separation of 3 different blood components - red blood cells, plasma and buffy-coat, obtained through the process of centrifugation and extraction.

    The primary bag contains CPD anticoagulant solution and one satellite bag contains SAG-M additive solution for red blood cell preservation. 

    Imported Film

    Ultra Sharp Needle

    Customized Accessories

    Item No.

    Anti-Coagulant

    Capacity

    Needle

    X- means with NP,SP CT

     TB-T450CS(X)

    CPD+SAG-M

      450/400/400 (450/300/300) ml

     16G

     TB- T500CS(X)

    CPD+SAG-M

      500/400/400  ml

      16G

  • Send Inquiry
  • T&B QUADRUPLE BLOOD BAG
  • Blood Transfusion System

    T&B Blood Bag System

    For whole blood collection and separation of 4 different blood components - red blood cells, plasma, leukocytes and platelets, obtained through the process of centrifugation and extraction.

    The primary bag contains CPD anticoagulant solution and one satellite bag contains SAG-M additive solution for red blood cell preservation. 

    One satellite bag is for 5-day platelet storage.  

    Imported Film

    Ultra Sharp Needle

    Customized Accessories

    Item No.

    Anti-Coagulant

    Capacity

    Needle

    X- means with NP,SP CT

     

     

     

     TB-Q450CS(X)

    CPD+SAG-M

      450/400/400 (450/300/300) ml

     16G

     TB- Q500CS(X)

    CPD+SAG-M

      500/400/400  ml

      16G

  • Send Inquiry
  • Leukocyte Filter System
  • Blood Transfusion System

    Filtration System

    Product Description

    Fosmedic developed the Leukocyte-reduction filter system that meet the regulatory guidelines and strict requirements of blood banks in Europe and the US markets.

    Leukocyte-reduction filter system is designed for reducing the white blood cells in whole blood or red blood cell conentrates, preventing lots of ill-reaction in transfusion and reducing implant-anti-host and virus diseases from non-self's white blood cells.

    This product is for removal of leukocyte in whole blood or MAP solution and for storage of MAP solution and clinical transfusion, no permission for any other usage.

    • Leukocyte reduction ≥ 99.9%, residual white blood cells ≤ 2.5 X 106/unit
    • Red cells recovery ≥ 85%

    Anticoagulant:CPD+SAG-M

    Primary Bag Capacity: 350ml,450ml,500ml

    Satellite Bag Capacity: Available from 150ml to 450ml

    Needle Gauge Size:16G

  • Send Inquiry
  • Whole Blood Filtration System
  • Blood Transfusion System

    Filtration System

    For whole blood collection and in-line -filtration of whole blood components, obtaining leucoreduced red blood cells and leucoreduced plasma through the process of centrifugation and extraction. 

    Imported Film

    Ultra Sharp Needle

    Customized Accessories

    Reduction Rate 99.99%

    Residual Leukocyte <1.0*106/unit

    Red Blood Cell Recovery ≥90%

    <1.0*106 leukocytes per unit

    <0.8% hemolysis

    >85% red cell recovery

    < 30min filtration time

  • Send Inquiry